| Literature DB >> 30934536 |
Song Chen1, Mai Yu2, Junwu Kan3, Jianping Li4, Zhonghua Zhang5, Xinyi Xie6, Xiaomin Wang7.
Abstract
A new concept of a dual-chamber serial-parallel piezoelectric pump with an integrated sensor (DSPPIS) is presented in this paper. By means of dividing a piezoelectric bimorph into an actuator and a sensor, sensing function is integrated onto the DSPPIS for flow rate measurement. A prototype of the DSPPIS was manufactured and assembled from a finished piezoelectric bimorph. Then, frequency and voltage characteristics were tested to evaluate the performance of the DSPPIS with serial and parallel connection. Experimental results show that the optimal frequency range of DSPPIS can be achieved and determined by itself through monitoring the sensing voltage when driven by a fixed voltage of 150 Vpp and a frequency range of 40⁻400 Hz. For a fixed frequency of 100 Hz and a voltage range of 50⁻250 Vpp, both the sensing voltage and output flow rate increase with the increase of driving voltage. It is observed that there is a positive correlation between sensing voltage and output flow rate, which was further fitted by using linear function. The correlation coefficients for the DSPPIS with serial and parallel connection are calculated as 0.9716 and 0.9054, respectively. As a result, the DSPPIS demonstrated in this paper has realized the measurement of flow rate without the additional flow-sensing equipment both in serial and parallel connection.Entities:
Keywords: integrated sensor; parallel connection; piezoelectric pump; serial connection
Year: 2019 PMID: 30934536 PMCID: PMC6472054 DOI: 10.3390/s19061447
Source DB: PubMed Journal: Sensors (Basel) ISSN: 1424-8220 Impact factor: 3.576
Figure 1Schematic cross-section and connection mode of a dual-chamber serial-parallel piezoelectric pump with an integrated sensor (DSPPIS).
Figure 2Schematic of the piezoelectric bimorph vibrator.
Parameters of DSPPIS.
| Type | Value and Material |
|---|---|
| Pump size | 41 mm × 41 mm × 25 mm |
| Pump material | PMMA |
| Check valve type | Umbrella valve |
| Check valve material | Silica gel |
| Diameter of metal substrate | 35 mm |
| Thickness of metal substrate | 0.4 mm |
| Diameter of ceramic | 28 mm |
| Thickness of ceramic | 0.2 mm |
| Height of chamber | 0.15 mm |
| Driving waveform | Sine wave |
Figure 3The 3-D assembly schematic of the DSPPIS.
Figure 4The schematic of the self-sensing test of the DSPPIS.
Figure 5Output flow rate and sensing voltage under a fixed voltage of 150 Vpp in serial connection.
Figure 6Output flow rate and sensing voltage under a fixed voltage of 150 Vpp in parallel connection.
Figure 7Output flow rate and sensing voltage under a fixed frequency of 100 Hz in serial connection.
Figure 8Output flow rate and sensing voltage under a fixed frequency of 100 Hz in parallel connection.
Figure 9The relationship between flow rate and sensing voltage at 100 Hz in serial connection.
Figure 10The relationship between flow rate and sensing voltage at 100 Hz in parallel connection.