Literature DB >> 30934041

A Randomized, Controlled, Multicenter Clinical Study Evaluating The Crestal Bone Level Change Of SLActive Bone Level Ø 3.3 mm Implants Compared To SLActive Bone Level Ø 4.1 mm Implants For Single-Tooth Replacement.

Saba Sameeh Ghazal, Guy Huynh-Ba, Tara Aghaloo, Serge Dibart, Stuart Froum, Robert O'Neal, David Cochran.   

Abstract

PURPOSE: The purpose of this prospective randomized clinical trial was to test the hypothesis that narrow-diameter titanium-zirconium (Ti-Zr) alloy implants with a chemically modified hydrophilic surface are not inferior in regard to crestal bone level change compared with standard-diameter implants with the same implant surface and material (control).
MATERIALS AND METHODS: This multicenter study included 50 patients in need of a single tooth replacement in the anterior (canine to canine) or premolar region of the mandible or maxilla. Patients were included if the site could accommodate a 4.1-mm-diameter implant. Implants were temporarily restored at 3 to 4 weeks after placement. Definitive restorations were delivered 4 to 6 months after placement. Patients returned 1 year after implant loading for clinical measurements and radiographic examination. The primary outcome was mean crestal bone level changes measured between implant loading and 12 months postloading. Secondary outcomes included implant success, survival, gingival recession, and patient satisfaction.
RESULTS: Fifty patients were enrolled; 47 completed the study. Twenty-three patients were in the narrow-diameter implant group (test), and 24 patients were in the standard-diameter implant group (control). The success and survival rates at 12 months postloading were 100% for both groups. The change in the mean crestal bone level from implant loading to 12 months postloading around narrow-diameter implants was -0.27 ± 0.34 mm. For the standard-diameter implants, the change was significantly higher at -0.48 ± 0.67 mm (P = .02). No significant difference was found in gingival recession and patient satisfaction.
CONCLUSION: The results of this prospective randomized clinical trial suggest noninferiority of the narrow- vs standard-diameter Ti-Zr implant. In addition, bone remodeling was less pronounced for the narrow-diameter implants.

Entities:  

Mesh:

Substances:

Year:  2019        PMID: 30934041     DOI: 10.11607/jomi.6927

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  2 in total

Review 1.  Evaluation of osseintegration between traditional and modified hydrophilic titanium dental implants - Systematic analysis.

Authors:  Geeta Arya; Varun Kumar
Journal:  Natl J Maxillofac Surg       Date:  2020-12-16

Review 2.  Bone loss-related factors in tissue and bone level dental implants: a systematic review of clinical trials.

Authors:  Hamed Mortazavi; Amin Khodadoustan; Aida Kheiri; Lida Kheiri
Journal:  J Korean Assoc Oral Maxillofac Surg       Date:  2021-06-30
  2 in total