Literature DB >> 30929082

Is patient satisfaction related to patient reported sounds from ceramic on ceramic total hip arthroplasty? A study of 265 hips.

Jonathan A Barrow1, Hiren M Divecha2, Sunil Panchani2, Richard Boden3, Amol Chitre2, Anil Gambhir2, Martyn L Porter2, Tim N Board2.   

Abstract

INTRODUCTION: The ideal method and implant to perform total hip arthroplasty (THA) is still a debated topic. Ceramic on ceramic (CoC) bearings have favourable wear properties, but squeaking has been reported as an unwanted side effect. We aimed to determine the rate of noise generation from CoC hips and investigate whether there is a relationship with patient satisfaction.
METHODS: A total of 246 consecutive CoC bearing uncemented THA were retrospectively identified in a single institution. Post-operatively patients were sent a postal questionnaire to evaluate their reported sounds and satisfaction with their THA. Uni- and multi-variate analyses were performed to identify potential predictor variables for reported post-operative sounds.
RESULTS: Questionnaires were returned by 172 patients (70% return rate). 24% reported sounds from their hips with 11% reporting a squeak. Median satisfaction levels were minimally, but significantly less for "noisy" (9/10) than "quiet" hips (10/10) (median difference = - 1, 95% CI - 2 to 0, p < 0.001). Compared to those with "noisy" hips, patients with "quiet" hips were 1.7 times (95% CI 1.3-2.5, p = 0.0002) more likely to report a "forgotten" hip. Younger age (p < 0.043) and increased anteversion (p < 0.021) were predictors for reported sounds.
CONCLUSION: We have identified a high rate of "noisy" hips in this series of CoC THA with a significant inverse relationship between "noisy" hips and patient satisfaction levels. In our unit, we are moving towards the use of ceramic on cross-linked polyethylene bearings as a result of these findings and the excellent survivorship of this bearing combination.

Entities:  

Keywords:  Arthroplasty; Ceramic; Hip; Noise; Squeak

Mesh:

Substances:

Year:  2019        PMID: 30929082     DOI: 10.1007/s00590-019-02426-2

Source DB:  PubMed          Journal:  Eur J Orthop Surg Traumatol        ISSN: 1633-8065


  3 in total

1.  Natural history of noise and squeaking in cementless ceramic-on-ceramic total hip arthroplasty.

Authors:  Kenta Inagaki; Satoshi Iida; Shuichi Miyamoto; Chiho Suzuki; Takushi Nakatani; Yoshiyuki Shinada; Yuya Kawarai; Shigeo Hagiwara; Junichi Nakamura; Sumihisa Orita; Seiji Ohtori
Journal:  J Orthop       Date:  2020-09-19

2.  Arthroscopic evaluation and treatment of a squeaking hip. A case report.

Authors:  Jonathan Bellity; Marc Elkaïm; Didier Hannouche; Rémy Nizard
Journal:  BMC Musculoskelet Disord       Date:  2020-12-03       Impact factor: 2.362

3.  Ceramic-on-ceramic versus ceramic-on-polyethylene in total hip arthroplasty: a comparative study at a minimum of 13 years follow-up.

Authors:  Malerba Giuseppe; Basilico Mattia; Bonfiglio Nadia; Vitiello Raffaele; Ruberto Pasquale; D' Adamio Stefano; Sirgiovanni Mattia; De Santis Vincenzo; Maccauro Giulio
Journal:  BMC Musculoskelet Disord       Date:  2022-01-17       Impact factor: 2.362

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.