Literature DB >> 30928579

Effectiveness of Sealants in Prevention of Cerebrospinal Fluid Leakage after Spine Surgery: A Systematic Review.

Ahmet Kinaci1, Nizar Moayeri2, Albert van der Zwan3, Tristan P C van Doormaal2.   

Abstract

BACKGROUND: Sealants are often used in spine surgery to prevent postoperative cerebrospinal fluid (CSF) leakage.
OBJECTIVE: To investigate the efficacy of sealants in preventing postoperative CSF leakage in spine surgery.
METHODS: The PubMed, Embase, and Cochrane databases were searched for articles reporting the outcome of patients treated with a sealant for spinal dural repair. The number of patients, indication of surgery, surgical site, applied technique, type of sealant used, and outcome in terms of postoperative CSF leakage were noted for each study. The primary outcome was CSF leakage in general and secondary outcome infection.
RESULTS: Forty-one articles were selected with a total of 2542 cases; there were 4 comparative studies with 540 sealed cases and 343 cases with primary suture closure only. The quantity of CSF leakage did not differ between the sealant group (50 of 540, 9.1%) and the group treated with sutures only (48 of 343, 13.8%) (risk ratio [RR], 0.58 [confidence interval [CI], 0.18-1.82]). The infection rate did also not differ between the sealant and primary suture groups (RR, 0.94 [CI, 0.55-1.61]). This result was found in both the intended and the unintended durotomy subgroups. Secondary analysis of all cases showed that endoscopic or minimally invasive surgery had lower CSF leakage rates compared with open surgery regardless of sealant use (RR, 0.18 [CI, 0.05-0.75]).
CONCLUSIONS: Currently available sealants seem not to reduce the rate of CSF leakage in spine surgery. In endoscopic and minimally invasive surgery, the CSF leakage rate is less frequent compared with open, conventional surgery regardless of sealant use.
Copyright © 2019 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Cerebrospinal fluid leakage; Dural sealant; Durotomy; Spinal surgery

Mesh:

Substances:

Year:  2019        PMID: 30928579     DOI: 10.1016/j.wneu.2019.02.236

Source DB:  PubMed          Journal:  World Neurosurg        ISSN: 1878-8750            Impact factor:   2.104


  7 in total

1.  Cerebrospinal Fluid Leak after Transsphenoidal Surgery: A Systematic Review and Meta-analysis.

Authors:  Emma M H Slot; Rengin Sabaoglu; Eduard H J Voormolen; Eelco W Hoving; Tristan P C van Doormaal
Journal:  J Neurol Surg B Skull Base       Date:  2021-08-20

2.  Effectiveness of Repair Techniques for Spinal Dural Tears: A Systematic Review.

Authors:  Elliot H Choi; Alvin Y Chan; Nolan J Brown; Brian V Lien; Ronald Sahyouni; Andrew K Chan; John Roufail; Michael Y Oh
Journal:  World Neurosurg       Date:  2021-02-25       Impact factor: 2.104

Review 3.  Direct Pars Defect Tubular Decompression and TLIF for the Treatment of Low-Grade Adult Isthmic Spondylolisthesis: Surgical Challenges and Nuances of a Muscle-Sparing Minimally Invasive Approach.

Authors:  Fabio Roberti; Katie Arsenault
Journal:  Minim Invasive Surg       Date:  2020-10-31

4.  Safety and biodegradability of a synthetic dural sealant patch (Liqoseal) in a porcine cranial model.

Authors:  Ahmet Kinaci; Wilhelmina Bergmann; Sander van Thoor; Saskia Redegeld; Albert van der Zwan; Tristan P C van Doormaal
Journal:  Animal Model Exp Med       Date:  2021-12-21

5.  Clinical Feasibility of Completely Autologous Fibrin Glue in Spine Surgery.

Authors:  Yuki Taniguchi; Yoshitaka Matsubayashi; Toshiyuki Ikeda; So Kato; Toru Doi; Yasushi Oshima; Hitoshi Okazaki; Sakae Tanaka
Journal:  Spine Surg Relat Res       Date:  2021-12-14

6.  Cerebrospinal fluid leaks following intradural spinal surgery-Risk factors and clinical management.

Authors:  Moritz Lenschow; Moritz Perrech; Sergej Telentschak; Niklas von Spreckelsen; Julia Pieczewski; Roland Goldbrunner; Volker Neuschmelting
Journal:  Front Surg       Date:  2022-09-20

7.  Ex vivo evaluation of a multilayered sealant patch for watertight dural closure: cranial and spinal models.

Authors:  A Kinaci; S van Thoor; S Redegeld; M Tooren; T P C van Doormaal
Journal:  J Mater Sci Mater Med       Date:  2021-07-23       Impact factor: 4.727