Cerebral foreign body reaction due to hydrophilic polymer embolization following aneurysm treatment by pipeline flow diversion device.

Thomas Rand Geisbush1, Michael P Marks2, Jeremy J Heit2.   

Abstract

The use of flow diverting stents for wide based, intracranial aneurysms has become an invaluable treatment option. While intracranial hemorrhage and ischemic stroke from dislodged atherosclerotic emboli are common adverse events, the potential for delayed granulomatous inflammation from possible hydrophilic polymer emboli is rarely recognized. We present a unique case in which visible chipping of the pusher wire for stent placement was observed, followed by clinical and radiographic evidence suggestive of a delayed foreign body reaction to intracranial hydrophilic polymer emboli. A 55-year-old woman underwent placement of a Pipeline embolization device for a left-sided, broad-based aneurysm at the base of the internal carotid artery and posterior communicating artery. Two months later she developed right-sided focal neurological deficits. Imaging showed ipsilateral focal edema and enhancing lesions with contrast. Although not confirmed with biopsy and histopathology, clinical and radiographic evidence suggests that this patient probably experienced a delayed foreign body reaction to hydrophilic polymer emboli from compromised procedural equipment during flow diverting stent placement. Although previously described, this is the first instance to our knowledge in whichvisible chipping of the pusher wire was observed on a Pipeline embolization device.

Entities:  

Keywords:  Granulomatous inflammation; cerebral aneurysm; flow diverting stent; foreign body reaction; hydrophilic polymer embolization

Mesh:

Substances:

Year:  2019        PMID: 30922199      PMCID: PMC6607610          DOI: 10.1177/1591019919830767

Source DB:  PubMed          Journal:  Interv Neuroradiol        ISSN: 1591-0199            Impact factor:   1.610


  3 in total

1.  Suspected Metallic Embolization Distal to Coiled Intracranial Aneurysms Detectable by Susceptibility-Weighted MR Imaging.

Authors:  D H Yoo; Y D Cho; H S Lee; S H Kim; D Jang; S H Lee; W-S Cho; H-S Kang; J E Kim; M H Han
Journal:  AJNR Am J Neuroradiol       Date:  2020-04       Impact factor: 3.825

Review 2.  Hydrophilic polymer embolization following flow diversion of cerebral aneurysms.

Authors:  Mohamad Abdalkader; Anvitha Sathya; Alice Ma; Anna M Cervantes-Arslanian; David Y Chung; Glenn Barest; Thanh N Nguyen
Journal:  Neuroradiol J       Date:  2021-03-26

3.  Intrathrombus polymer coating deposition: a pilot study of 91 patients undergoing endovascular therapy for acute large vessel stroke. Part I: Histologic frequency.

Authors:  Rashi I Mehta; Ansaar T Rai; Jeffrey A Vos; Orestes E Solis; Rupal I Mehta
Journal:  J Neurointerv Surg       Date:  2019-05-18       Impact factor: 5.836

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.