Literature DB >> 30919673

Variability among strain variables derived from two-dimensional speckle tracking echocardiography in dogs by use of various software.

Giorgia Santarelli, Marco Baron Toaldo, Jonathan Bouvard, Tony M Glaus, Josefa Fernández Del Palacio.   

Abstract

OBJECTIVE: To determine variability of global longitudinal strain (GLS) and strain rate (SR) measurements in dogs with and without cardiac disease derived from 2-D speckle tracking echocardiography (STE) by use of various software. ANIMALS: 2 cohorts comprising 44 dogs (23 cardiovascularly healthy and 21 with cardiac disease) and 40 dogs (18 cardiovascularly healthy and 22 with cardiac disease). PROCEDURES: Transthoracic echocardiographic images in each cohort were analyzed with vendor-independent software and vendor-specific 2-D STE software for each of 2 vendors. Values for GLS and SR obtained from the same left parasternal apical views with various software were compared. Intraobserver and interobserver variability was determined, and agreement among results for the various software was assessed.
RESULTS: Strain analysis was not feasible with vendor-independent software for 20% of images obtained with the ultrasonography system of vendor 1. Intraobserver and interobserver coefficient of variation was < 10% for GLS values, whereas SR measurements had higher variance. There was a significant difference in GLS and SR obtained for each cohort with different software. Evaluation of Bland-Altman plots revealed wide limits of agreement, with variance for GLS of up to 6.3 units in a single dog. CONCLUSIONS AND CLINICAL RELEVANCE: Results of longitudinal strain analysis were not uniform among software, and GLS was the most reproducible measurement. Significant variability in results among software warrants caution when referring to reference ranges or comparing serial measurements in the same patient because changes of < 6.5% in GLS might be within measurement error for different postprocessing software.

Entities:  

Mesh:

Year:  2019        PMID: 30919673     DOI: 10.2460/ajvr.80.4.347

Source DB:  PubMed          Journal:  Am J Vet Res        ISSN: 0002-9645            Impact factor:   1.156


  2 in total

1.  Tissue motion annular displacement to assess the left ventricular systolic function in healthy cats.

Authors:  Giovana Lais Ruviaro Tuleski; Marcela Wolf; Maria Jose Garcia Ribeiro Pscheidt; Júlio Pereira Dos Santos; Marlos Gonçalves Sousa
Journal:  Vet Res Commun       Date:  2022-03-08       Impact factor: 2.816

2.  Echocardiographic predictors of first onset of atrial fibrillation in dogs with myxomatous mitral valve disease.

Authors:  Marco Baron Toaldo; Chiara Mazzoldi; Giovanni Romito; Helen Poser; Barbara Contiero; Mario Cipone; Carlo Guglielmini
Journal:  J Vet Intern Med       Date:  2020-08-07       Impact factor: 3.333

  2 in total