Literature DB >> 30909015

Thionin functionalized signal amplification label derived dual-mode electrochemical immunoassay for sensitive detection of cardiac troponin I.

Hui Lv1, Yueyun Li2, Xiaobo Zhang1, Xinjin Li1, Zhen Xu1, Lei Chen1, Degang Li3, Yunhui Dong1.   

Abstract

A sensitive sandwich-type electrochemical immunosensor was established by employing Au@Pt core-shell multi-branched nanoparticles, and thionin functionalized nitrogen/sulfur co-doped graphene oxide (N/S-cGO/L-lys/Au@Pt MBs/Thi) as a double signal label to detect cardiac troponin I (cTnI). In this work, Au nanorods functionalized polydopamine (Au NR@PDA) with high adsorption capacity and superior electroconductivity can provide an efficient substrate for immobilizing primary antibodies (Ab1). In the proposed N/S-cGO/L-lys/Au@Pt MBs/Thi, an electrochemically active molecule, Thi was covalently bonded in the N/S-cGO/L-lys/Au@Pt MBs. It presented a strong differential pulse voltammetry (DPV) current signal without electron transfer mediators, and showed a high electrocatalytic activity toward H2O2 reduction by using amperometric i-t (i-t). Impressively, with the synergistic effect of N/S-cGO/L-lys/Au@Pt MBs/Thi and Au NR@PDA, the developed dual-mode electrochemical immunosensor for cTnI detection showed a wide linear concentration range (50 fg/mL to 250 ng/mL, 750 fg/mL to 100 ng/mL) and a low detection limit (16.7 fg/mL, 250 fg/mL) via i-t and DPV, respectively. Furthermore, this immunosensor exhibited acceptable reproducibility, high sensitivity and good stability under optimal conditions. More importantly, the satisfactory results were obtained in detection of cTnI-spiked human serum samples, and the presented method may be a promising application in clinical bioanalysis.
Copyright © 2019 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Amperometric i-t; Cardiac troponin I; Differential pulse voltammetry; Double signal label; Sandwich-type electrochemical immunosensor

Mesh:

Substances:

Year:  2019        PMID: 30909015     DOI: 10.1016/j.bios.2019.03.033

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  4 in total

1.  Electrochemical determination of sulfamethazine using a gold electrode modified with multi-walled carbon nanotubes, graphene oxide nanoribbons and branched aptamers.

Authors:  Baoshan He; Ming Li; Mannan Li
Journal:  Mikrochim Acta       Date:  2020-04-18       Impact factor: 5.833

2.  An ultrasensitive ratiometric immunosensor based on the ratios of conjugated distyrylbenzene derivative nanosheets with AIECL properties and electrochemical signal for CYFRA21-1 detection.

Authors:  Xiaoyi Lv; Mengmeng Bi; Xiaoyun Xu; Yanping Li; Chao Geng; Bo Cui; Yishan Fang
Journal:  Anal Bioanal Chem       Date:  2021-11-05       Impact factor: 4.142

3.  Fluorescence Based on Surface Plasmon Coupled Emission for Ultrahigh Sensitivity Immunoassay of Cardiac Troponin I.

Authors:  Vien Thi Tran; Heongkyu Ju
Journal:  Biomedicines       Date:  2021-04-21

Review 4.  Electroanalytical point-of-care detection of gold standard and emerging cardiac biomarkers for stratification and monitoring in intensive care medicine - a review.

Authors:  Robert D Crapnell; Nina C Dempsey; Evelyn Sigley; Ascanio Tridente; Craig E Banks
Journal:  Mikrochim Acta       Date:  2022-03-12       Impact factor: 6.408

  4 in total