Literature DB >> 30909003

Objective parameters to measure (in)stability of the knee joint during gait: A review of literature.

Jim C Schrijvers1, Josien C van den Noort2, Martin van der Esch3, Joost Dekker4, Jaap Harlaar5.   

Abstract

BACKGROUND: Instability of the knee joint during gait is frequently reported by patients with knee osteoarthritis or an anterior cruciate ligament rupture. The assessment of instability in clinical practice and clinical research studies mainly relies on self-reporting. Alternatively, parameters measured with gait analysis have been explored as suitable objective indicators of dynamic knee (in)stability. RESEARCH QUESTION: This literature review aimed to establish an inventory of objective parameters of knee stability during gait.
METHODS: Five electronic databases (Pubmed, Embase, Cochrane, Cinahl and SPORTDiscuss) were systematically searched, with keywords concerning knee, stability and gait. Eligible studies used an objective parameter(s) to assess knee (in)stability during gait, being stated in the introduction or methods section. Out of 10717 studies, 89 studies were considered eligible.
RESULTS: Fourteen different patient populations were investigated with kinematic, kinetic and/or electromyography measurements during (challenged) gait. Thirty-three possible objective parameters were identified for knee stability, of which the majority was based on kinematic (14 parameters) or electromyography (12 parameters) measurements. Thirty-nine studies used challenged gait (i.e. external perturbations, downhill walking) to provoke knee joint instability. Limited or conflicting results were reported on the validity of the 33 parameters. SIGNIFICANCE: In conclusion, a large number of different candidates for an objective knee stability gait parameter were found in literature, all without compelling evidence. A clear conceptual definition for dynamic knee joint stability is lacking, for which we suggest : "The capacity to respond to a challenge during gait within the natural boundaries of the knee". Furthermore biomechanical gait laboratory protocols should be harmonized, to enable future developments on clinically relevant measure(s) of knee stability during gait.
Copyright © 2019 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Biomechanics; Gait; Knee; Measurement; Stability

Mesh:

Year:  2019        PMID: 30909003     DOI: 10.1016/j.gaitpost.2019.03.016

Source DB:  PubMed          Journal:  Gait Posture        ISSN: 0966-6362            Impact factor:   2.840


  1 in total

1.  Acoustic emissions and kinematic instability of the osteoarthritic knee joint: comparison with radiographic findings.

Authors:  Mika T Nevalainen; Olli Veikkola; Jerome Thevenot; Aleksei Tiulpin; Jukka Hirvasniemi; Jaakko Niinimäki; Simo S Saarakkala
Journal:  Sci Rep       Date:  2021-10-01       Impact factor: 4.379

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.