Literature DB >> 30905375

Evaluation of the tubing material and physical dimensions on the performance of extraction columns for on-line sample preparation-LC-MS/MS.

Ana Lúcia de Toffoli1, Edvaldo Vasconcelos Soares Maciel1, Fernando Mauro Lanças2.   

Abstract

Nowadays, high analytical throughputs are required considering an increasing demand for faster, simple and improved methods to analyze contaminants in a considerable number of samples. Generally, these compounds are present in complex matrices in contact with a high number of interferents becoming their determination difficult at low concentration. In this context, on-line extraction techniques arose to improve the extraction as well as separation power, while minimizing errors related to human sample manipulation. This paper describes a study regarding the development and optimization of columns used as an extraction device in multidimensional liquid chromatography. The main goals were the evaluation of the material used as column body as well as the investigation of the tube dimensions (internal diameter and length) in the extraction performance. Firstly, several tube materials were tested (steel, fused silica, PEEK, among others) being steel whose reported the best performance and was consequently chose for further studies. The investigation about the effects of the columns physical dimensions revealed a linear relationship between performance and the amount of sorbent utilized as extractive phase. However, when different columns with same amount of sorbent were tested results suggests that both i.d. and lengths play an important role in extraction efficiency. The longest columns with lower internal diameter showed the best results favoring the radial as well as axial analytes diffusion into the extraction column. After evaluation of these column variables, applications were carried out employing several different analytes belonging to various chemical classes and practical utilization, in order to reinforce the versatility as well as the robustness of this proposed study.
Copyright © 2019 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Automated analysis; Extraction column; Graphene oxide; Multidimensional liquid chromatography; On-line extraction; Sample preparation

Mesh:

Year:  2019        PMID: 30905375     DOI: 10.1016/j.chroma.2019.03.023

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  3 in total

1.  A cartridge-based device for automated analyses of solid matrices by online sample prep-capillary LC-MS/MS.

Authors:  Edvaldo Vasconcelos Soares Maciel; Fernando Mauro Lanças
Journal:  Anal Bioanal Chem       Date:  2022-02-02       Impact factor: 4.142

2.  Multidimensional Liquid Chromatography Employing a Graphene Oxide Capillary Column as the First Dimension: Determination of Antidepressant and Antiepileptic Drugs in Urine.

Authors:  Edvaldo Vasconcelos Soares Maciel; Ana Lúcia de Toffoli; Jussara da Silva Alves; Fernando Mauro Lanças
Journal:  Molecules       Date:  2020-02-29       Impact factor: 4.411

3.  Evaluation of Two Fully Automated Setups for Mycotoxin Analysis Based on Online Extraction-Liquid Chromatography-Tandem Mass Spectrometry.

Authors:  Edvaldo Vasconcelos Soares Maciel; Karen Mejía-Carmona; Fernando Mauro Lanças
Journal:  Molecules       Date:  2020-06-15       Impact factor: 4.411

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.