Literature DB >> 30905000

Laparoscopic pectopexy: a follow-up cyclic biomechanical analysis determining time to functional stability.

A Sauerwald1, L Langer2,3, D Ratiu3, A Prescher4, M Scaal5, G K Noé6, K Wegmann7, D R Bulian8, C Eichler9,10.   

Abstract

INTRODUCTION: Pectopexy, a laparoscopic method for prolapse surgery, showed promising results in previous transient testing by this group. It was shown that a single suture, yielding an ultimate load of 35 N, was equivalent to continuous suturing. This was demonstrated in an in vitro cadaver study. This transient data were used to establish an elastic stress-strain envelope. It was now possible to proceed to dynamic in vitro analysis of this surgical method to establish time to functional stability.
METHODS: Cyclic testing of this fixation method was performed on human female embalmed cadaver (cohort 1) and fresh, non-embalmed cadaver (cohort 2) pelvises. The testing envelope was 5-25 N at a speed of 1 mm/s. 100 load regulated cycles were applied.
RESULTS: 100 cycles were completed with each model; no overall system failure occurred. Steady state, i.e., functional stability was reached after 14.5 (± 2.9) cycles for the embalmed group and after 19.1 (± 7.2) cycles for the non-embalmed group. This difference was statistically significant p = 0.00025.
CONCLUSION: This trial showed in an in vitro cyclic testing of the pectopexy method that functional stability may be achieved after no more than 19.1 cycles of load exposure. When remaining within the established load envelope of below 25 N, patients do not need to fear global fixation failure. Testing did demonstrate differences in non-embalmed and embalmed cadaver testing. Embalmed cadaver testing tends to underestimate time to steady state by 26.3%.

Entities:  

Keywords:  Analysis; Biomechanic; Biomechanical; Cyclic testing; Dynamic; In vitro; Laparoscopic; Pectopexy

Mesh:

Year:  2019        PMID: 30905000     DOI: 10.1007/s00404-019-05117-9

Source DB:  PubMed          Journal:  Arch Gynecol Obstet        ISSN: 0932-0067            Impact factor:   2.344


  1 in total

1.  Tacks vs. sutures: a biomechanical analysis of sacral bony fixation methods for laparoscopic apical fixations in the porcine model.

Authors:  Alina Katharina Jansen; Sebastian Ludwig; Wolfram Malter; Axel Sauerwald; Jens Hachenberg; Caroline Pahmeyer; Kilian Wegmann; Claudia Rudroff; Leonidas Karapanos; Julia Radosa; Nadja Trageser; Christian Eichler
Journal:  Arch Gynecol Obstet       Date:  2021-11-29       Impact factor: 2.344

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.