Calculation of photon dose distributions in an inhomogeneous medium using convolutions.

A L Boyer, E C Mok.   

Abstract

A formulation of the single energy photon transport problem is cast in the form of a series of convolutions over the primary fluence distribution with invariant kernels. A method is developed for compensating for the variant intervoxel attenuation in the scattered dose distribution by means of an invariant correction kernel. Results of applying the formulation to 60Co distributions in the presence of slab and block inhomogeneities are presented.

Mesh:

Substances:

Year:  1986        PMID: 3090410     DOI: 10.1118/1.595964

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  6 in total

1.  Estimation of focal and extra-focal radiation profiles based on Gaussian modeling in medical linear accelerators.

Authors:  Shigeo Anai; Hidetaka Arimura; Katsumasa Nakamura; Fujio Araki; Takaomi Matsuki; Hideki Yoshikawa; Satoshi Yoshidome; Yoshiyuki Shioyama; Hiroshi Honda; Nobuo Ikeda
Journal:  Radiol Phys Technol       Date:  2011-03-24

2.  Characterization of Compton-scatter imaging with an analytical simulation method.

Authors:  Kevin C Jones; Gage Redler; Alistair Templeton; Damian Bernard; Julius V Turian; James C H Chu
Journal:  Phys Med Biol       Date:  2018-01-11       Impact factor: 3.609

3.  On the quantification of the dosimetric accuracy of collapsed cone convolution superposition (CCCS) algorithm for small lung volumes using IMRT.

Authors:  Oscar I Calvo; Alonso N Gutiérrez; Sotirios Stathakis; Carlos Esquivel; Nikos Papanikolaou
Journal:  J Appl Clin Med Phys       Date:  2012-05-10       Impact factor: 2.102

4.  Clinical implications in the use of the PBC algorithm versus the AAA by comparison of different NTCP models/parameters.

Authors:  Antonella Bufacchi; Barbara Nardiello; Roberto Capparella; Luisa Begnozzi
Journal:  Radiat Oncol       Date:  2013-07-04       Impact factor: 3.481

5.  Pinnacle3 modeling and end-to-end dosimetric testing of a Versa HD linear accelerator with the Agility head and flattening filter-free modes.

Authors:  Daniel L Saenz; Ganesh Narayanasamy; Wilbert Cruz; Nikos Papanikolaou; Sotirios Stathakis
Journal:  J Appl Clin Med Phys       Date:  2016-01-08       Impact factor: 2.102

6.  Comparison of commercially available three-dimensional treatment planning algorithms for monitor unit calculations in the presence of heterogeneities.

Authors:  J R Butts; A E Foster
Journal:  J Appl Clin Med Phys       Date:  2001       Impact factor: 2.102

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.