Literature DB >> 30900769

Attenuated total reflection Fourier-transform infrared (ATR-FTIR) spectroscopy to diagnose osteoarthritis in equine serum.

M Paraskevaidi1, P D Hook2, C L M Morais1, J R Anderson3, R White4, P L Martin-Hirsch5, M J Peffers3, F L Martin1.   

Abstract

BACKGROUND: Reliable and validated biomarkers for osteoarthritis (OA) are currently lacking.
OBJECTIVES: To develop an accurate and minimally invasive method to assess OA-affected horses and provide potential spectral markers indicative of disease. STUDY
DESIGN: Observational, cross-sectional study.
METHODS: Our cohort consisted of 15 horses with OA and 48 without clinical signs of the disease, which were used as controls. Attenuated total reflection Fourier-transform infrared (ATR-FTIR) spectroscopy was used to investigate serum samples (50 μL) collected from these horses. Spectral processing and multivariate analysis revealed differences and similarities, allowing for detection of spectral biomarkers that discriminated between the two cohorts. A supervised classification algorithm, namely principal component analysis coupled with quadratic discriminant analysis (PCA-QDA), was applied to evaluate the diagnostic accuracy.
RESULTS: Segregation between the two different cohorts, OA-affected and controls, was achieved with 100% sensitivity and specificity. The six most discriminatory peaks were attributed to proteins and lipids. Four of the spectral peaks were elevated in OA horses, which could be potentially due to an increase in lipids, protein expression levels and collagen, all of which have been previously reported in OA. Two peaks were found decreased and were tentatively assigned to the reduction of proteoglycan content that is observed during OA. MAIN LIMITATIONS: The control group had a wide range of ages and breeds. Presymptomatic OA cases were not included. Therefore, it remains unknown whether this test could also be used as an early diagnostic tool.
CONCLUSIONS: This spectrochemical approach could provide an accurate and cost-effective blood test, facilitating point-of-care diagnosis of equine OA.
© 2019 EVJ Ltd.

Entities:  

Keywords:  biomarkers; horse; horse osteoarthritis; infrared spectroscopy; point-of-care testing; serum diagnostics

Mesh:

Year:  2019        PMID: 30900769     DOI: 10.1111/evj.13115

Source DB:  PubMed          Journal:  Equine Vet J        ISSN: 0425-1644            Impact factor:   2.888


  3 in total

1.  Diagnosis of Systemic Diseases Using Infrared Spectroscopy: Detection of Iron Overload in Plasma-Preliminary Study.

Authors:  Leonardo Barbosa Leal; Marcelo Saito Nogueira; Jandinay Gonzaga Alexandre Mageski; Thiago Pereira Martini; Valério Garrone Barauna; Leonardo Dos Santos; Luis Felipe das Chagas E Silva de Carvalho
Journal:  Biol Trace Elem Res       Date:  2021-01-07       Impact factor: 3.738

2.  Investigations into the Effects of pH on Quantitative Measurements of Lactate in Biological Media Using ATR-FTIR Spectroscopy.

Authors:  Nystha Baishya; Mohammad Mamouei; Karthik Budidha; Meha Qassem; Pankaj Vadgama; Panayiotis A Kyriacou
Journal:  Molecules       Date:  2020-08-13       Impact factor: 4.411

Review 3.  Vibrational Spectroscopy in Assessment of Early Osteoarthritis-A Narrative Review.

Authors:  Chen Yu; Bing Zhao; Yan Li; Hengchang Zang; Lian Li
Journal:  Int J Mol Sci       Date:  2021-05-15       Impact factor: 5.923

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.