| Literature DB >> 30900420 |
Young Joo Kim1, Jung Sik Huh1, Kyung Kgi Park2.
Abstract
PURPOSE: To explore the effect of bi-parametric MRI-ultrasound (MR/US) fusion prostate biopsy on the detection of overall cancer and significant prostate cancer (sPCa).Entities:
Keywords: MRI; Prostate cancer; diffusion; image-guided biopsy; ultrasound
Mesh:
Substances:
Year: 2019 PMID: 30900420 PMCID: PMC6433566 DOI: 10.3349/ymj.2019.60.4.346
Source DB: PubMed Journal: Yonsei Med J ISSN: 0513-5796 Impact factor: 2.759
Patient Characteristics
| Systemic random biopsy | MR/US fusion biopsy | Combined biopsy | |
|---|---|---|---|
| No. of men | 140 | 97 | 97 |
| Age (yr) | 66.4 | 67.6 | 67.2 |
| PSA (ng/mL), median (IQR) | 8.2 (4.2 –10.7) | 8.0 (4.1 –9.7) | 8.1 (4.1 –10.2) |
| prostate volume (cm3), median (IQR) | 49.0 (36 –71) | 48.0 (34 –54) | 47.2 (34 –71) |
| PSA density, median (IQR) | 0.16 (0.09 –0.21) | 0.16 (0.08 –0.19) | 0.16 (0.08 –0.21) |
| PI-RADS score on bp-MRI (n) | |||
| 1 | 9 | ||
| 2 | 34 | ||
| 3 | 57 | 57 | 57 |
| 4 | 30 | 30 | 30 |
| 5 | 10 | 10 | 10 |
| Biopsy results | |||
| Negative for cancer (n) | 80 | 51 | 48 |
| Positive for cancer (Gleason score) (n) | |||
| 6 (3+3) and low volume 7 (3+4) | 33 | 16 | 17 |
| >low volume 7 (3+4) and <8 | 10 | 10 | 10 |
| ≥8 | 17 | 20 | 22 |
| Detection rate (%)* | 42.86 | 47.42 | 50.52 |
| Significant prostate cancer (%)* | 45.00 | 65.22 | 65.31 |
| Insignificant prostate cancer (%)* | 55 | 34.78 | 34.69 |
PSA, prostate-specific antigen; MR/US, MRI-ultrasound, combined biopsy: systemic random biopsy with MR/US fusion biopsy; PI-RADS, Prostate Imaging Reporting and Data System; sPCa, clinically significant prostate cancer.
*There is no difference between MR/US fusion biopsy and combined biopsy; however, there are significant differences compared to systemic biopsy.
Combined Biopsy Results according to PI-RADS Score
| PI-RADS score | Gleason score from prostate biopsy | sPCa positive rate (%) | Overall positive rate (%) | |||
|---|---|---|---|---|---|---|
| No cancer | 3+3 and low volume 3+4 | High volume 3+4 | More than 4+3 | |||
| 1 | 6 | 3 | 0.0 | 33.3 | ||
| 2 | 20 | 9 | 2 | 3 | 14.7 | 41.2 |
| 3 | 34 | 12 | 3 | 8 | 19.3 | 40.4 |
| 4 | 13 | 4 | 4 | 9 | 43.3 | 56.7 |
| 5 | 1 | 1 | 3 | 5 | 80.0 | 90.0 |
PI-RADS, Prostate Imaging Reporting and Data System; sPCa, clinically significant prostate cancer.
Concordance between Systemic Biopsy and MR/US Fusion Prostate Biopsy according to Risk
| Fusion biopsy | Systemic random biopsy | |||
|---|---|---|---|---|
| No ca | Low | Intermediate | High | |
| PI-RADS 3 | ||||
| No ca | 34 | 1 | 2 | |
| Low | 4 | 7 | ||
| Intermediate | 1 | 2 | ||
| High | 2 | 2 | 2 | |
| PI-RADS 4 | ||||
| No ca | 13 | |||
| Low | 4 | |||
| Intermediate | 2 | 2 | ||
| High | 2 | 1 | 6 | |
| PI-RADS 5 | ||||
| No ca | 1 | |||
| Low | 1 | |||
| Intermediate | 1 | 2 | 1 | |
| High | 1 | 3 | ||
| PI-RADS 3–5 | ||||
| No ca | 48 | 1 | 0 | 2 |
| Low | 4 | 12 | 0 | 0 |
| Intermediate | 0 | 4 | 6 | 1 |
| High | 0 | 4 | 4 | 11 |
MR/US, MRI-ultrasound; Fusion biopsy, MR/US fusion prostate biopsy; PI-RADS, Prostate Imaging Reporting and Data System.
Fig. 1Negative and positive predictive values according to lesion and PI-RADS score. The numbers at the bottom of the graph are PI-RADS scores. Total biopsy detection rate: 47.1% (66/140). *p=0.019, †p<0.001 (There was a significant difference between PZ and TZ in PI-RADS 3 and 4). PPV, positive predictive value; cPCa, clinically significant prostate cancer; NPV, negative predictive value; PZ, peripheral zone of the prostate; TZ, transitional zone of the prostate.