Yigu Chen 1 , Kevin R Anderson 1 , Jia Xu 1 , Jeffrey D Goldsmith 1,2 , Yael K Heher 1 . Show Affiliations »
Abstract
OBJECTIVES: An intraoperative consultation (IOC) checklist was developed and implemented aimed at standardizing slide labeling and monitoring metrics central to quality and safety in surgical pathology. DESIGN: Data were collected for all IOC cases over a 9-month period. Slide labeling defect rates and IOC turnaround time (TAT) were recorded and compared for the pre- and postimplementation periods. RESULTS: In total, 839 IOC cases were analyzed. Preintervention slide labeling showed that 85% of cases contained at least one defect (n = 565). Postintervention data revealed that 27% of cases contained at least one defect (n = 274). The improvement was statistically significant (P < .001). Mean TAT was 21.6 minutes preintervention vs 23.2 minutes postintervention, and the change was insignificant (P = .071). CONCLUSIONS: The implementation of a standardized IOC reduced slide labeling error. This improvement did not affect mean TAT and may have the increased quality of IOC TAT data reporting. Other metrics affecting patient safety and quality were monitored and standardized. © American Society for Clinical Pathology, 2019. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
OBJECTIVES: An intraoperative consultation (IOC) checklist was developed and implemented aimed at standardizing slide labeling and monitoring metrics central to quality and safety in surgical pathology. DESIGN: Data were collected for all IOC cases over a 9-month period. Slide labeling defect rates and IOC turnaround time (TAT) were recorded and compared for the pre- and postimplementation periods. RESULTS: In total, 839 IOC cases were analyzed. Preintervention slide labeling showed that 85% of cases contained at least one defect (n = 565). Postintervention data revealed that 27% of cases contained at least one defect (n = 274). The improvement was statistically significant (P < .001). Mean TAT was 21.6 minutes preintervention vs 23.2 minutes postintervention, and the change was insignificant (P = .071). CONCLUSIONS: The implementation of a standardized IOC reduced slide labeling error. This improvement did not affect mean TAT and may have the increased quality of IOC TAT data reporting. Other metrics affecting patient safety and quality were monitored and standardized. © American Society for Clinical Pathology, 2019. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Entities: Species
Keywords:
Frozen section; Intraoperative consultation; Patient safety; Quality improvement; Safety
Mesh: See more »
Year: 2019
PMID: 30892600 DOI: 10.1093/ajcp/aqz009
Source DB: PubMed Journal: Am J Clin Pathol ISSN: 0002-9173 Impact factor: 2.493