Literature DB >> 30889418

Protocol optimization for cardiac and liver iron content assessment using MRI: What sequence should I use?

Christian A Barrera1, Hansel J Otero2, Helge D Hartung3, David M Biko2, Suraj D Serai2.   

Abstract

OBJECTIVE: To determine the optimal MRI protocol and sequences for liver and cardiac iron estimation in children.
METHODS: We evaluated patients ≤18 years with cardiac and liver MRIs for iron content estimation. Liver T2 was determined by a third-party company. Cardiac and Liver T2* values were measured by an observer. Liver T2* values were calculated using the available liver parenchyma in the cardiac MRI. Linear correlations and Bland-Altman plots were run between liver T2 and T2*, cardiac T2* values; and liver T2* on dedicated cardiac and liver MRIs.
RESULTS: 139 patients were included. Mean liver T2 and T2* values were 8.6 ± 5.4 ms and 4.5 ± 4.1 ms, respectively. A strong correlation between liver T2 and T2* values was observed (r = 0.96, p < 0.001) with a bias (+4.1 ms). Mean cardiac bright- and dark-blood T2* values were 26.5 ± 12.9 ms and 27.2 ± 11.9 ms, respectively. Cardiac T2* values showed a strong correlation (r = 0.81, p < 0.001) with a low bias (-1.0 ms). The mean liver T2* on liver and cardiac MRIs were 4.9 ± 4.7 ms and 4.6 ± 3.9 ms, respectively. A strong correlation between T2* values was observed (r = 0.96, p < 0.001) with a small bias (-0.2 ms).
CONCLUSION: MRI protocols for iron concentration in the liver and the heart can be simplified to avoid redundant information and reduce scan time. In most patients, a single breath-hold GRE sequence can be used to evaluate the iron concentration in both the liver and heart.
Copyright © 2019 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Children; Heart; Liver; MRI; Protocol; T2; T2 star

Mesh:

Substances:

Year:  2019        PMID: 30889418     DOI: 10.1016/j.clinimag.2019.02.012

Source DB:  PubMed          Journal:  Clin Imaging        ISSN: 0899-7071            Impact factor:   1.605


  2 in total

1.  Rosette Trajectories Enable Ungated, Motion-Robust, Simultaneous Cardiac and Liver T2 * Iron Assessment.

Authors:  Adam M Bush; Christopher M Sandino; Shreya Ramachandran; Frank Ong; Nicholas Dwork; Evan J Zucker; Ali B Syed; John M Pauly; Marcus T Alley; Shreyas S Vasanawala
Journal:  J Magn Reson Imaging       Date:  2020-05-26       Impact factor: 4.813

Review 2.  Basics of magnetic resonance imaging and quantitative parameters T1, T2, T2*, T1rho and diffusion-weighted imaging.

Authors:  Suraj D Serai
Journal:  Pediatr Radiol       Date:  2021-04-15
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.