In vitro color stainability and relative translucency of CAD-CAM restorative materials used for laminate veneers and complete crowns.

Rabia Arif1, Burak Yilmaz2, William M Johnston3.   

Abstract

STATEMENT OF PROBLEM: Assessing the long-term stainability and durability of restorative materials is an important parameter for determining clinical success and longevity. Information remains limited regarding the color stainability and translucency of the recently introduced ceramic materials for restorative treatment.
PURPOSE: The purpose of this in vitro study was to compare the effect of cyclic immersion in hot and cold coffee on the color stainability and translucency of 6 computer-aided design and computer-aided manufacturing (CAD-CAM) restorative materials at thicknesses which represent a laminate veneer and a complete crown.
MATERIAL AND METHODS: CAD-CAM restorative materials including zirconia-reinforced lithium silicate ceramic (Celtra Duo), lithium disilicate glass-ceramic (IPS e.max CAD), polymerized resin nanoceramic (Lava Ultimate), integrated ceramic and acrylate polymer network material (VITA ENAMIC), zirconia-reinforced lithium silicate (VITA SUPRINITY), and zirconia (VITA YZ HT) were studied in 2 thicknesses for laminate veneer (0.7 mm) and complete crown application (1.3 mm to 1.5 mm). For each specimen, color difference on a gray backing was calculated using a spectroradiometer between its baseline color and after 6000 cycles of coffee thermocycling. The colors of the specimens on the black and white backings were used to calculate the relative translucency parameter from the CIEDE2000 color difference formula. An ANOVA and the Bonferroni-corrected Student t tests were used for testing statistical significance (α=.05).
RESULTS: No difference was found among the means of color change after coffee thermocycling between any 2 materials for the crown thickness (P>.999), and no difference was found among the means of color change between the 2 thickness groups within each material (P≥.187). However, the mean color change of the resin nanoceramic material in laminate veneer application (0.7 mm) was greater than that of every other material in the veneer thickness group (P<.001), and the mean color change of the integrated ceramic and acrylate polymer network material was greater than that of the lithium disilicate glass-ceramic material studied at the veneer thickness (P=.014). Translucency was found to be lower for complete crown thickness compared with laminate veneer thickness within each combination of material and coffee thermocycling (P<.001). The translucency of the lithium disilicate glass-ceramic material studied at the laminate veneer thickness was also found to be higher after coffee thermocycling (P=.033). Furthermore, several differences among materials were found for each combination of thickness and coffee.
CONCLUSIONS: Color change after coffee thermocycling of the resin nanoceramic material was beyond the acceptability threshold. The lower translucency found for crown thickness compared with veneer thickness was verified.
Copyright © 2018 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2019        PMID: 30885587     DOI: 10.1016/j.prosdent.2018.09.011

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  9 in total

1.  Effect of thickness, cement shade, and coffee thermocycling on the optical properties of zirconia reinforced lithium silicate ceramic.

Authors:  Gülce Çakmak; Mustafa Borga Donmez; Afnan Kashkari; William M Johnston; Burak Yilmaz
Journal:  J Esthet Restor Dent       Date:  2021-08-13       Impact factor: 3.040

2.  Effect of Potassium Aluminum Sulfate Application on the Viability of Fibroblasts on a CAD-CAM Feldspathic Ceramic before and after Thermocycling.

Authors:  Gülce Çakmak; Canan Akay; Mustafa Borga Donmez; Emre Mumcu; Handan Sevim Akan; Rafat Sasany; Samir Abou-Ayash; Burak Yilmaz
Journal:  Materials (Basel)       Date:  2022-06-15       Impact factor: 3.748

3.  The minimum thickness of a multilayer ceramic restoration required for masking dark background.

Authors:  Niloofar Shadman; Shahram Farzin Ebrahimi; Maryam Azizi Shoul; Saeideh Gorji Kandi; Setare Rostami
Journal:  Dent Res J (Isfahan)       Date:  2022-04-27

4.  Load-to-Failure Resistance and Optical Characteristics of Nano-Lithium Disilicate Ceramic after Different Aging Processes.

Authors:  Mustafa Borga Donmez; Emin Orkun Olcay; Münir Demirel
Journal:  Materials (Basel)       Date:  2022-06-05       Impact factor: 3.748

5.  Final Colour of Ultratranslucent Multilayered Zirconia Veneers, Effect of Thickness, and Resin Cement Shade.

Authors:  Seyed Reza Khosravani; Mehdi Abed Kahnamoui; Soodabeh Kimyai; Elmira Jafari Navimipour; Farzaneh Sadeghi Mahounak; Fatemeh Pournaghi Azar
Journal:  Biomed Res Int       Date:  2022-06-01       Impact factor: 3.246

6.  Spectrophotometric evaluation of color errors generated in the visual color duplication procedure for current ceramic veneers.

Authors:  Xue-Dong Bai; Yu-Zhu Yan; Qing Li
Journal:  J Dent Sci       Date:  2020-07-04       Impact factor: 2.080

7.  Color and Translucency Stability of Three-Dimensional Printable Dental Materials for Crown and Bridge Restorations.

Authors:  Jong-Eun Kim; Won-Huy Choi; Dasun Lee; Yooseok Shin; Sung-Ho Park; Byoung-Duck Roh; Dohyun Kim
Journal:  Materials (Basel)       Date:  2021-01-31       Impact factor: 3.623

8.  Effect of Staining and Aging on Translucency Parameter of CAD-CAM Materials.

Authors:  Rubens Nisie Tango; Ana Todorović; Dejan Stamenković; Duygu Narin Karasan; Irena Sailer; Rade Dušan Paravina
Journal:  Acta Stomatol Croat       Date:  2021-03

9.  Effect of CAD/CAM Ceramic Thickness on Shade Masking Ability of Discolored Teeth: In Vitro Study.

Authors:  Passent Ellakany; Marwa Madi; Nourhan M Aly; Zainb S Al-Aql; Maher AlGhamdi; Abdulrahman AlJeraisy; Adel S Alagl
Journal:  Int J Environ Res Public Health       Date:  2021-12-18       Impact factor: 3.390

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.