Literature DB >> 30882963

Repeatability of wide-field choroidal thickness measurements using enhanced-depth imaging optical coherence tomography.

Hosein Hoseini-Yazdi1, Stephen J Vincent1, Michael J Collins1, Scott A Read1, David Alonso-Caneiro1.   

Abstract

BACKGROUND: To examine the repeatability of choroidal thickness measurements across a 55° field, in a sample of healthy young adults using wide-field enhanced-depth imaging optical coherence tomography.
METHODS: High-resolution wide-field volumetric enhanced-depth imaging scans were obtained from the right eye of 27 adults (mean age 27 ± 5 years) during two sessions, separated by 19 ± 15 days, using the follow-up feature of the Spectralis instrument, while controlling for confounding factors known to influence choroidal thickness. Semi-automatic segmentation of the choroidal boundaries was corrected by a single masked observer. This process was repeated on images from the first session of 12 randomly selected subjects, allowing the intersession (n = 27) and intraobserver (n = 12) co-efficients of repeatability for regional measures of choroidal thickness to be calculated.
RESULTS: The observer-related variability in choroidal thickness was highest at the fovea (intraobserver co-efficient of repeatability [95% confidence interval], 13 [7-19] μm, p < 0.001), then reduced gradually toward the perifovea (2 [1-4] μm, p < 0.001), and plateaued in the near-peripheral (2 [1-3] μm) and peripheral (4 [2-6] μm) regions. The intersession variability improved significantly from the fovea (intersession co-efficient of repeatability [95% confidence interval], 27 [16-38] μm, p < 0.01) and parafovea (25 [15-36] μm, p < 0.02) toward the periphery (16 [10-23] μm).
CONCLUSION: Wide-field choroidal thickness measurements using enhanced-depth imaging optical coherence tomography are highly repeatable in the macular region, and improve in precision in more peripheral regions in healthy young adults. A change of up to 38 and 28 μm is required to distinguish true clinical change from measurement variability in individual measurements of macular and extra-macular choroidal thickness, respectively.
© 2019 Optometry Australia.

Entities:  

Keywords:  choroidal thickness; enhanced-depth imaging; optical coherence tomography; repeatability; wide-field imaging

Mesh:

Year:  2019        PMID: 30882963     DOI: 10.1111/cxo.12893

Source DB:  PubMed          Journal:  Clin Exp Optom        ISSN: 0816-4622            Impact factor:   2.742


  5 in total

1.  Choroidal thickness changes in children with chronic heart failure due to dilated cardiomyopathy.

Authors:  Klaudia Rakusiewicz; Krystyna Kanigowska; Wojciech Hautz; Lidia Ziółkowska
Journal:  Int Ophthalmol       Date:  2021-05-09       Impact factor: 2.031

2.  Astigmatic Defocus Leads to Short-Term Changes in Human Choroidal Thickness.

Authors:  Hosein Hoseini-Yazdi; Stephen J Vincent; Scott A Read; Michael J Collins
Journal:  Invest Ophthalmol Vis Sci       Date:  2020-07-01       Impact factor: 4.799

3.  Comparison of choroidal thickness measurements using swept source and spectral domain optical coherence tomography in pachychoroid diseases.

Authors:  Min-Woo Lee; Hye-Jin Park; Yong-Il Shin; Woo-Hyuk Lee; Hyung-Bin Lim; Jung-Yeul Kim
Journal:  PLoS One       Date:  2020-02-26       Impact factor: 3.240

4.  Repeatability and inter-observer variation of choroidal thickness measurements using swept-source optical coherence tomography in myopic danish children aged 6-14 years.

Authors:  Anders Asmussen; Bjarke S Smith; Flemming Møller; Trine M Jakobsen
Journal:  Acta Ophthalmol       Date:  2021-06-14       Impact factor: 3.988

5.  A metrological approach to the analysis of choroidal thickness by optical coherence tomography 3D scans in myopia research.

Authors:  Katharina Breher; Arne Ohlendorf; Siegfried Wahl
Journal:  Sci Rep       Date:  2019-12-30       Impact factor: 4.379

  5 in total