Literature DB >> 30882147

Cryobiopsy during flex-rigid pleuroscopy: an emerging alternative biopsy method in malignant pleural mesothelioma. A comparative study of pathology.

Toshiyuki Nakai1, Yuji Matsumoto1,2, Shinji Sasada1,3, Midori Tanaka1, Takaaki Tsuchida1, Yuichiro Ohe2, Noriko Motoi4.   

Abstract

BACKGROUND: Malignant pleural mesothelioma (MPM) is rarely an asbestos-related cancer with a poor prognosis that is difficult to distinguish from some benign conditions by using conventional biopsy techniques. The purpose of this study was to evaluate the utility of a novel biopsy technique using a cryoprobe during flex-rigid pleuroscopy for diagnosing MPM.
METHODS: Consecutive patients who underwent pleural cryobiopsy during flex-rigid pleuroscopy from June through November 2017 to diagnose the cause of pleural effusion were collected. From these, cases ultimately diagnosed as MPM were selected. Pleural biopsies were performed by using conventional instruments followed by a cryoprobe. The obtained samples were histologically examined and compared with regard to the quality (sample size, tissue depth, and crush rate), immunohistochemical (IHC) staining, and p16 by fluorescence in situ hybridization (FISH).
RESULTS: In total, five patients ultimately diagnosed as MPM were enrolled. The sample collected was significantly larger for cryobiopsy than conventional biopsy (18.9 mm2 vs. 6.7 mm2, P < 0.001). Full-thickness biopsies were achieved in four cases by using cryobiopsy compared with one case by conventional biopsy. Moreover, the crush rate was significantly less for cryobiopsy than conventional biopsy (9% vs. 35%, P < 0.001). The results of IHC staining and p16 by FISH were similar between biopsy techniques. Cryobiopsy successfully led to accurate diagnosis of MPM in all cases, whereas conventional biopsy was diagnostic in one case. No severe complications developed after either biopsy technique.
CONCLUSION: Cryobiopsy during flex-rigid pleuroscopy is a feasible and convenient biopsy technique that supports precise diagnosis of MPM.
© The Author(s) 2019. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

Entities:  

Keywords:  Malignant pleural mesothelioma; cryobiopsy; flex-rigid pleuroscopy; full-thickness pleural biopsy

Mesh:

Year:  2019        PMID: 30882147     DOI: 10.1093/jjco/hyz032

Source DB:  PubMed          Journal:  Jpn J Clin Oncol        ISSN: 0368-2811            Impact factor:   3.019


  3 in total

1.  Efficacy and Safety of Pleural Cryobiopsy vs. Forceps Biopsy for Evaluation of Undiagnosed Pleural Effusion: A Systematic Review and Meta-Analysis.

Authors:  Mohan Giri; Haiyun Dai; Shuliang Guo; Yishi Li; Lin He; Rongjuan Zhuang
Journal:  Front Med (Lausanne)       Date:  2022-04-11

2.  Precut technique using an injection needle: A retrospective study on a new ancillary procedure for pleural biopsy.

Authors:  Yasuyuki Mizumori; Katsuya Hirano; Nobuya Hirata; Ryota Hiraoka; Sayaka Takahashi; Ryota Kominami; Kohei Miyake; Masaki Takenouchi; Tomohiro Kato; Sachie Kume; Sachiko Higashino; Yasuharu Nakahara; Tetsuji Kawamura
Journal:  Medicine (Baltimore)       Date:  2022-08-05       Impact factor: 1.817

3.  Pleural cryobiopsy during local anaesthetic thoracoscopy in dry pleural dissemination.

Authors:  Ayn Marie Lao; Yuji Matsumoto; Midori Tanaka; Takafumi Matsunaga; Shinji Sasada; Takaaki Tsuchida
Journal:  Respirol Case Rep       Date:  2019-11-27
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.