| Literature DB >> 30882075 |
Su-In Hwang1, Eun-Jung Lee1, Geun-Pyo Hong1.
Abstract
This study investigated the effects of temperature (50°C, 55°C, and 60°C) and time (12 and 24 h) on the cookery properties of sous-vide (SV) processed pork loin. As an indicator of cookery properties, cooking loss, expressible moisture (EM), pH, differential scanning calorimetry (DSC), shear force, total plate count (TPC) and CIE color were measured and compared with fresh (FC) and cooked control (CC, 75°C for 30 min). SV treatments at 50°C showed higher tenderness and lower cooking loss comparing to CC. DSC result indicated that thermal transition of collagen was a key factor affecting the cooking loss and shear force of meat. In comparison of CC, risks of insufficient pasteurization and uncooked color generation were not shown in SV processed meat. Therefore, the results indicated that SV had a potential advantage to produce tender and moist meat, and the best SV condition of pork loin was estimated at 50°C for 24 h.Entities:
Keywords: cookery property; pork loin; sous-vide; temperature; time
Year: 2019 PMID: 30882075 PMCID: PMC6411237 DOI: 10.5851/kosfa.2019.e4
Source DB: PubMed Journal: Food Sci Anim Resour ISSN: 2636-0772
Effects of temperature and time on physicochemical properties of sous-vide processed pork loin
| Treatments | Quality parameters | |||||||
|---|---|---|---|---|---|---|---|---|
| Cooking loss (%) | EM (%) | pH | Shear force (N) | TPC (Log CFU/g) | CIE L* | CIE a* | CIE b* | |
| FC | NE | 8.65±4.71[ | 5.68±0.02[ | NE | 3.81±0.25 | 41.5±1.51[ | 6.33±0.66[ | 14.7±2.70[ |
| CC | 32.6±1.55[ | 12.9±1.75[ | 5.81±0.02[ | 69.1±6.36[ | ND | 47.9±3.87[ | 4.90±0.72[ | 17.7±1.15[ |
| 50°C,12h | 14.5±2.09[ | 20.2±4.94[ | 5.79±0.01[ | 51.8±1.73[ | ND | 49.9±3.99[ | 3.83±0.58[ | 18.2±0.87[ |
| 50°C, 24 h | 11.6±0.89[ | 19.6±0.78[ | 5.89±0.02[ | 25.2±4.03[ | ND | 46.4±2.78[ | 4.37±1.04[ | 19.3±1.30[ |
| 55°C, 12 h | 21.1±1.69[ | 15.7±2.53[ | 5.95±0.04[ | 38.9±3.41[ | ND | 51.1±3.05[ | 3.73±0.29[ | 15.1±0.43[ |
| 55°C, 24 h | 19.8±1.24[ | 19.7±3.88[ | 5.93±0.02[ | 36.6±4.12[ | ND | 55.1±4.28[ | 4.10±0.42[ | 15.7±1.11[ |
| 60°C, 12 h | 21.7±0.84[ | 15.2±5.68[ | 5.93±0.03[ | 23.4±12.1[ | ND | 50.6±2.03[ | 4.07±0.29[ | 17.3±2.41[ |
| 60°C, 24 h | 23.5±1.14[ | 13.5±0.96[ | 6.04±0.04[ | 21.3±8.57[ | ND | 52.6±4.13[ | 3.50±0.50[ | 16.0±3.30[ |
Means with different superscript within same column are significantly different (p<0.05).
FC, fresh control; CC, cooked control; EM, expressible moisture; TPC, total plate count; NE, not estimated; ND, not detected.
Fig. 1.DSC thermogram of sous-vide processed pork loin (representative data from duplication).
FC indicates fresh control. Arrows are the maximum denaturation temperature of meat proteins. CC, cooked control; SV, sous-vide; FC, fresh control; DSC, differential scanning calorimetry.