Gas chromatography with tandem cold electron ionization mass spectrometric detection and vacuum ultraviolet detection for the comprehensive analysis of fentanyl analogues.

Sydney Buchalter1, Ioan Marginean1, Joshua Yohannan2, Ira S Lurie3.   

Abstract

Fentanyl and its derivatives are amongst the ever-growing list of emerging drugs which are impinging on current traditional analytical techniques employed in forensic laboratories. To avoid current regulations, fentanyl analogues are being illicitly synthesized by slight alterations of functional groups to the fentanyl skeleton leading to inaccurate identifications, thus posing the greatest challenge to laboratories. In this study, a novel analytical technique is presented in which gas chromatography (GC) is interfaced with both cold electron ionization mass spectrometric (cold EI MS) and vacuum ultraviolet (VUV) detection by the means of a flow splitter for the simultaneous qualitative and quantitative analysis of twenty-four fentanyl analogues, including seven sets of positional isomers. For most of the twenty-four analogues, enhanced molecular ions were obtained with at least 1% intensity relative to base peak. In addition to enhanced molecular ions, the GC-cold EI MS maintained fragmentation pathways observed by GCMS with classical electron ionization. For the most part, VUV detection resulted in unique VUV spectra for fentanyl analogues including positional isomers. The combination of these two complementary detectors in tandem with the high resolving power of the gas chromatograph, allows for higher confidence in analyte identification by the combination of retention times, cold EI mass spectra and VUV spectra. The preferred method for quantitation was based on VUV detection and offered excellent determination coefficients (R2≥0.999) for most analytes over two orders of magnitude dynamic range, without the need for deuterated internal standards. For both run-to-run and day-to-day repeatability studies, at moderate solute concentrations, the correct fentanyl related compound was identified in almost every instance from a library containing all the fentanyl analogues plus hundreds of other analytes.
Copyright © 2019 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Cold electron ionization mass spectrometric detection; Fentanyl analogues; Positional isomers; Vacuum ultraviolet detection

Mesh:

Substances:

Year:  2019        PMID: 30876740     DOI: 10.1016/j.chroma.2019.03.011

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  3 in total

1.  Application of the fentanyl analog screening kit toward the identification of emerging synthetic opioids in human plasma and urine by LC-QTOF.

Authors:  Logan C Krajewski; Kenneth D Swanson; William A Bragg; Rebecca L Shaner; Craig Seymour; Melissa D Carter; Elizabeth I Hamelin; Rudolph C Johnson
Journal:  Toxicol Lett       Date:  2019-12-05       Impact factor: 4.372

2.  Quantitative analysis of smokeless powder particles in post-blast debris via gas chromatography/vacuum ultraviolet spectroscopy (GC/VUV).

Authors:  Madison Reavis; John Goodpaster
Journal:  J Forensic Sci       Date:  2022-04-03       Impact factor: 1.717

3.  Mass-Spectrometry-Based Identification of Synthetic Drug Isomers Using Infrared Ion Spectroscopy.

Authors:  Ruben F Kranenburg; Fred A M G van Geenen; Giel Berden; Jos Oomens; Jonathan Martens; Arian C van Asten
Journal:  Anal Chem       Date:  2020-04-29       Impact factor: 6.986

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.