Literature DB >> 30872005

Inter-day reliability of the Upper Body Test for shoulder and pelvic girdle stability in adults.

Alan Dos Santos Fontes1, Marta Silva Santos2, Marcos Bezerra de Almeida2, Pedro J Marín3, Danilo Rodrigues Pereira da Silva2, Marzo E Da Silva-Grigoletto2.   

Abstract

BACKGROUND: There are a limited number of tests for the assessment of shoulder and pelvic girdle stability. Reliable instruments are important to evaluate movement dysfunction at these joints in order to provide more objective parameters.
OBJECTIVE: To evaluate the inter-day reliability of the Upper Body Test in young adults.
METHODS: A reliability study was carried out with three assessments of the shoulder and pelvic girdle stability within 48-h intervals (Monday, Wednesday, and Friday). The OctoBalance® platform was used to perform the Upper Body Test in 31 active young adults (24.5±8 years). Intraclass Correlation Coefficient (ICC2,2) two-way mixed model, Coefficient of Variation, and Bland-Altman plots were used to verify the reliability of the test. The standard error of measurement (SEM) and the minimum detectable difference (MDD95%) were calculated for clinical applicability.
RESULTS: The Intraclass Correlation Coefficient ranged from 0.87 to 0.94 - Featuring a mean difference of 0.89 (95%CI=-0.19-1.97) to left and 0.95 (95%CI=-0.38-2.27) for the right side, with a low variation coefficient (3.31-5.91%) between the second and third days of assessment. There was a statistically significant difference between the first assessment day and the other test sessions. The Bland-Altman analyses revealed low bias with scores within the limits of agreement. Minimum detectable difference scores were between 4.02 and 5.10, and standard error of measurement between 1.75 and 2.72, depending on the movement side.
CONCLUSION: The Upper Body Test presented good inter-day reliability for assessing the stability of the shoulder and pelvic girdle in young active healthy adults.
Copyright © 2019 Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia. Publicado por Elsevier Editora Ltda. All rights reserved.

Entities:  

Keywords:  Core stability; Physical tests; Physical therapy; Reproducibility

Year:  2019        PMID: 30872005     DOI: 10.1016/j.bjpt.2019.02.009

Source DB:  PubMed          Journal:  Braz J Phys Ther        ISSN: 1413-3555            Impact factor:   3.377


  2 in total

1.  French validation of the Weight Efficacy Life-Style questionnaire (WEL): Links with mood, self-esteem and stress among the general population and a clinical sample of individuals with overweight and obesity.

Authors:  Natalija Plasonja; Anna Brytek-Matera; Greg Décamps
Journal:  PLoS One       Date:  2021-11-16       Impact factor: 3.240

2.  Assessing Orthorexia Nervosa: Validation of the Polish Version of the Eating Habits Questionnaire in a General Population Sample.

Authors:  Anna Brytek-Matera; Natalija Plasonja; Greg Décamps
Journal:  Nutrients       Date:  2020-12-14       Impact factor: 6.706

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.