Robust Fetal Heart Beat Detection via R-Peak Intervals Distribution.

Chen Lin, Chien-Hung Yeh, Cheng-Yen Wang, Wenbin Shi, Bess Ma F Serafico, Chen-Hsu Wang, Chung-Hau Juan, Hsu-Wen Vincent Young, Yenn-Jiang Lin, Hui-Ming Yeh, Men-Tzung Lo.   

Abstract

Monitoring fetal heart rate during pregnancy is essential to assist clinicians in making more timely decisions. Non-invasive monitoring of fetal heart activities using abdominal ECGs is useful for diagnosis of heart defects. However, the extracted fetal ECGs are usually too weak to be robustly detected. Thus, it is a necessity to enhance fetal R-peak since their peaks may be hidden within the signal due to the immaturity of the fetal cardiovascular system. Therefore, to improve the detection of the fetal heartbeat, a novel fetal R-peak enhancement technique was proposed to statistically generate the weighting mask according to the distribution of the neighboring temporal intervals between each pair of peaks. Two sets of simulations were designed to validate the reliability of the method: challenges with different levels of (1) noise contamination and (2) R-peak interval changing rate. The simulation results showed that the weighting mask improved the accuracy of the R-peak detection rate by 25% and decreased the false alarm rate by 20% with white noise contamination, and ensured high R-peak detection rate (>80%), especially with mild noise contamination (noise amplitude ratio <1.5 and noise rate per minute <25%). For the simulations with continuous R-peak intervals changing, the masking process can still effectively eliminate noise contamination especially when the amplitude of the sinusoidal fetal R-R intervals is lower than 50 ms. For the real fetus ECGs, the detection rate was increased by 3.498%, whereas the false alarm rate was decreased by 3.933%. Next, we implemented the fetal R-peak enhancement technique to investigate fractal regulation and multiscale entropy of the real fetal heartbeat intervals. Both scaling exponent (∼0.6 to ∼1 in scale 4-15) and entropy measure (scale 6-10) increased with gestational ages (22-40 weeks). The results confirmed fractal slope and complexity of fetal heartbeat intervals can reflect the maturation of fetus organism.

Entities:  

Mesh:

Year:  2019        PMID: 30869605     DOI: 10.1109/TBME.2019.2904014

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  2 in total

1.  Waveform changes with the evolution of beta bursts in the human subthalamic nucleus.

Authors:  Chien-Hung Yeh; Bassam Al-Fatly; Andrea A Kühn; Anders C Meidahl; Gerd Tinkhauser; Huiling Tan; Peter Brown
Journal:  Clin Neurophysiol       Date:  2020-06-29       Impact factor: 3.708

2.  Non-linear Methods Predominant in Fetal Heart Rate Analysis: A Systematic Review.

Authors:  Maria Ribeiro; João Monteiro-Santos; Luísa Castro; Luís Antunes; Cristina Costa-Santos; Andreia Teixeira; Teresa S Henriques
Journal:  Front Med (Lausanne)       Date:  2021-11-30
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.