Literature DB >> 30864647

Influence of an Alternative Implant Design and Surgical Protocol on Primary Stability.

Mariana Lima da Costa Valente1, Denise Tornavoi de Castro1, Antônio Carlos Shimano2, Andréa Cândido Dos Reis1.   

Abstract

The purpose of thisin vitrostudy was to evaluate the influence of a new proposal of implant design and surgical protocol on primary stability in different bone densities. Four groups were tested (n=9): G1 - tapered, cone morse, Ø 4.3 mm x 10 mm in length (Alvim CM); G2 - experimental tapered; G3 - cylindrical, cone morse, Ø 4.0 mm x 11 mm in length (Titamax CM) and G4 - experimental cylindrical. The experimental implants were obtained from a design change in the respective commercial models. The insertion was performed in polyurethane (PU) blocks 0.24 g/cm3(20 pcf) and 0.64 g/cm3(40 pcf), according to different surgical protocols. The primary stability was measured by means of insertion torque (IT) and pullout test. Data were analyzed by ANOVA, Tukey's test (α=0.05) and Pearson's correlation. For IT and pullout, conventional and experimental implants showed no difference between them when inserted in the 20 pcf PU (p>0.05). In the 40 pcf PU, the modified implants exhibited greater IT (p<0.05) and lower pullout (p<0.05) compared to the respective conventional models. The implant design tested associated with the surgical protocol, positively influenced primary stability in higher density bones.

Entities:  

Mesh:

Substances:

Year:  2019        PMID: 30864647     DOI: 10.1590/0103-6440201902324

Source DB:  PubMed          Journal:  Braz Dent J        ISSN: 0103-6440


  3 in total

1.  In vitro evaluation of the influence of bone cortical thickness on the primary stability of conventional- and short-sized implants.

Authors:  Luiz-Antônio-Borelli Barros; Caio-Fossalussa da Silva; Germana-de Villa Camargos; Elcio Marcantonio; Guilherme-José-Pimentel-Lopes de Oliveira; Luiz-Antônio-Borelli Barros-Filho
Journal:  J Clin Exp Dent       Date:  2022-02-01

Review 2.  Relationship between dental implant macro-design and osseointegration: a systematic review.

Authors:  Simone Kreve; Izabela Ferreira; Mariana Lima da Costa Valente; Andréa Cândido Dos Reis
Journal:  Oral Maxillofac Surg       Date:  2022-09-29

3.  A novel anatomic titanium mesh cage for reducing the subsidence rate after anterior cervical corpectomy: a finite element study.

Authors:  Yuhang Wang; Yi Zhan; Huiming Yang; Hua Guo; Haiping Zhang; Qinpeng Zhao; Dingjun Hao; Biao Wang
Journal:  Sci Rep       Date:  2021-07-28       Impact factor: 4.379

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.