Literature DB >> 30862403

Computed tomography-guided dual localization with microcoil and patent blue vital dye for deep-seated pulmonary nodules in thoracoscopic surgery.

Chi-Wei Lin1, Huan-Jang Ko2, Shun-Mao Yang3, Yi-Chang Chen4, Wei-Chun Ko5, Hsin-Chieh Huang6, Jin-Shing Chen1, Yeun-Chung Chang5.   

Abstract

BACKGROUND/
PURPOSE: In video-assisted thoracic surgery (VATS) resection of small lung nodules, preoperative dye marking around the visceral pleura provides surface localization to help initiate resection, while implantation of a fiducial marker such as a microcoil can provide inner localization to aid nodule resection under fluoroscopic guidance. We aimed to determine whether dual localization with microcoil placement and dye marking is safe and useful for guiding the resection of small deep-seated lung nodules.
METHODS: We retrospectively evaluated data pertaining to 39 consecutive patients (40 nodules) managed between January 2016 and December 2017 in our hospital. Dual localization with patent blue V dye and microcoil was performed preoperatively because the pulmonary nodules were expected to be difficult to visualize or palpate intraoperatively. The patients underwent computed tomography-guided dual localization in a single puncture and were then transferred to the operation room. Intraoperative fluoroscopy was used to ensure that the lung tissue resected included the microcoil.
RESULTS: All 40 lesions were successfully resected using the dual localization technique followed by fluoroscopy-assisted thoracoscopic surgery. The median lesion diameter and depth were 0.9 and 1.7 cm, respectively, while the median margin/diameter ratio in the first resected specimen was 1.25. One patient had failure of localization due to partial release of the microcoil into the chest wall. Localization-related pneumothorax was detected in six of 39 patients (15.4%) and was always self-limited.
CONCLUSION: Dual localization with microcoil placement and dye marking is safe and supports successful VATS resection of small deep-seated lung nodules.
Copyright © 2019 Formosan Medical Association. Published by Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Dye; Localization; Microcoil; Pulmonary nodule

Mesh:

Year:  2019        PMID: 30862403     DOI: 10.1016/j.jfma.2019.02.005

Source DB:  PubMed          Journal:  J Formos Med Assoc        ISSN: 0929-6646            Impact factor:   3.282


  7 in total

1.  The risk factors for the failure of hook wire localization of ground glass nodules prior to thoracoscopic surgery.

Authors:  Musu Ala; Junzhong Liu; Jieli Kou; Xinhua Wang; Minfeng Sun; Changcheng Hao; Jianlin Wu
Journal:  J Cardiothorac Surg       Date:  2022-05-11       Impact factor: 1.522

2.  Comparison of CT-guided localization using hook wire or coil before thoracoscopic surgery for ground glass nodules.

Authors:  Junzhong Liu; Xinhua Wang; Yongming Wang; Minfeng Sun; Changsheng Liang; Liqing Kang
Journal:  Br J Radiol       Date:  2020-04-29       Impact factor: 3.039

3.  Computed Tomography-Guided Methylene Blue Localization: Single vs. Multiple Lung Nodules.

Authors:  Chia-Ying Lin; Chao-Chun Chang; Li-Ting Huang; Ta-Jung Chung; Yi-Sheng Liu; Yi-Ting Yen; Yau-Lin Tseng
Journal:  Front Med (Lausanne)       Date:  2021-04-14

4.  Non-intubated Thoracoscopic Surgery to Minimize Contamination From Airway Secretions During the COVID-19 Pandemic.

Authors:  Man-Ling Wang; Ming-Hui Hung; Hsao-Hsun Hsu; Ya-Jung Cheng; Jin-Shing Chen
Journal:  Front Surg       Date:  2022-02-18

5.  Implementation of sodium alginate-Fe3O4 to localize undiagnosed small pulmonary nodules for surgical management in a preclinical rabbit model.

Authors:  Zhi-Xuan Zhang; Lu Lv; Ai-Hua Shi; Yun-Hao Li; Tian-Ren Wang; Yuan-Hang Guo; Bao-Juan Hu; Xiao-Peng Yan; Jun-Ke Fu; Feng Ma; Hao-Hua Wang; Yi Lv; Yong Zhang
Journal:  Sci Rep       Date:  2022-06-15       Impact factor: 4.996

6.  A Simple Method to Improve Intraoperative Localization of Fiducial Markers during Lung Resections.

Authors:  Shengliang He; Staci Beamer; Dawn Jaroszewski; Jonathan D'Cunha; Samine Ravanbakhsh
Journal:  Thorac Cardiovasc Surg Rep       Date:  2022-09-30

7.  A computed tomography-based nomogram to predict pneumothorax caused by preoperative localization of ground glass nodules using hook wire.

Authors:  Junzhong Liu; Changsheng Liang; Xinhua Wang; Minfeng Sun; Liqing Kang
Journal:  Br J Radiol       Date:  2020-11-05       Impact factor: 3.039

  7 in total