Literature DB >> 30858040

Autologous Conditioned Plasma for tendon healing following arthroscopic rotator cuff repair. Prospective comparative assessment with magnetic resonance arthrography at 6 months' follow-up.

Jean-Charles Aurégan1, Shahnaz Klouche2, Bruno Levy3, Thomas Bauer3, Benoit Rousselin3, Mathieu Ferrand3, Philippe Hardy4.   

Abstract

INTRODUCTION: Despite improvements in technique and materials for rotator cuff repair, mean re-tear rates remain close to 30%. The aim of the present study was to assess injection of Autologous Conditioned Plasma (ACP™, Arthrex) for tendon healing after arthroscopic repair. The study hypothesis was that ACP™ improves the tendon-healing rate. MATERIAL AND
METHOD: A non-randomized comparative prospective study included all patients aged over 18 years operated on in 2010 for arthroscopic repair of full-thickness rotator cuff tear with≤2 fatty degeneration on the Goutallier classification, whatever the severity of retraction, on virgin non-osteoarthritic shoulder without contraindications for magnetic resonance (MR) arthrography. The surgical protocol was standardized. The first half of the patient sample received end-of-procedure ACP™ injection to the repaired tendon, tuberosity freshening surface and subacromial space, and the second (control) half received no supplementary treatment. The main endpoint was tendon healing on MR arthrography at 6 months according to Sugaya. Secondary endpoints comprised shoulder pain at rest on a numerical scale (0=no pain to 10=worst imaginable pain) and Constant functional score.
RESULTS: Two of the 58 patients refused MR arthrography and 7 were lost to follow-up. Forty-nine patients (26 ACP™, 23 controls) were analyzed: 20 male, 29 female; mean age, 61±7.3 years. There were no significant intergroup differences in healing rate at 6 months (ACP™ 73.1% vs. 78.3% controls; p=0.75), shoulder pain (2±1.8 vs. 2.6±1.7, respectively; p=0.24), or Constant score (77±13.5/100 vs. 72.4±12.3, respectively; p=0.18).
CONCLUSION: Associating ACP™ did not improve healing after arthroscopic rotator cuff repair. Sample size, however, had been calculated for a large expected difference, leading to lack of power. LEVEL OF EVIDENCE: III; case-control study.
Copyright © 2019 Elsevier Masson SAS. All rights reserved.

Entities:  

Keywords:  Arthroscopy; Autologous Conditioned Plasma (ACP™); Platelet-rich plasma; Rotator cuff tear; Tendon healing

Mesh:

Year:  2019        PMID: 30858040     DOI: 10.1016/j.otsr.2019.01.003

Source DB:  PubMed          Journal:  Orthop Traumatol Surg Res        ISSN: 1877-0568            Impact factor:   2.256


  2 in total

Review 1.  Systematic Review of Platelet-Rich Plasma for Rotator Cuff Repair: Are We Adhering to the Minimum Information for Studies Evaluating Biologics in Orthopaedics?

Authors:  Madeleine G DeClercq; Alyson M Fiorentino; Haylie A Lengel; Joseph J Ruzbarsky; Sara K Robinson; Verena T Oberlohr; Kaitlyn E Whitney; Peter J Millett; Johnny Huard
Journal:  Orthop J Sports Med       Date:  2021-12-07

Review 2.  Application of Platelet-Rich Plasma in Arthroscopic Rotator Cuff Repair: A Systematic Review and Meta-analysis.

Authors:  Wennan Xu; Qingyun Xue
Journal:  Orthop J Sports Med       Date:  2021-07-13
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.