Literature DB >> 30856521

Field tests of cubic-meter scale microbial electrochemical system in a municipal wastewater treatment plant.

Weihua He1, Yue Dong1, Chao Li1, Xiaoyu Han1, Guohong Liu1, Jia Liu1, Yujie Feng2.   

Abstract

A pilot microbial electrochemical system (MES) system with a total volume of 1.5 m3 was developed and operated outdoor in a municipal wastewater treatment plant (WWTP). Microbial separator based on the dynamic biofilm on low-cost porous matrix was applied to replace ion exchange membranes (IEMs), while the separate plug-in module architecture allowed the totally 336 pairs of MES units and 14 separator modules to be integrated into one wastewater tank. The separator layer equally divided the wastewater tank into 7 cathodic and 8 anodic compartments. Fed with primary sedimentation tank effluent of WWTP, the pilot MES achieved stable removal efficiency for chemical oxygen demand (91 ± 3%), total nitrogen (64 ± 2%) and ammonium nitrogen (91 ± 3%), which were complied with the first grade A standard of pollutants for municipal wastewater treatment plant (DSPMWTP) in China. The stable power output of pilot MES was 406 ± 30 mW m-3 based on effective liquid volume, or energy conversion performance of 2.03 × 10-3 kWh m-3 (one cubic meter of influent wastewater). The pilot MES achieved much lower effluent COD of 25 ± 7 mg L-1 with HRT of 5 h, while that of activated sludge process in WWTP was 43 ± 6 mg L-1 under HRT of 12 h. Even though the aeration of biocathode demanded a net electricity consumption of 3.44 × 10-3 kWh m-3, the low operation energy requirement for pilot MES was only 12% of that in a typical activated sludge process (0.3 kWh m-3). By avoiding the utilization of IEMs and redundant structural materials, the pilot MES achieved a low system cost of $1702.1 (or $1135 m-3) as well and promoted the further real-world application of MES.
Copyright © 2019. Published by Elsevier Ltd.

Entities:  

Keywords:  Energy and economic analysis; Field tests of wastewater treatment; Microbial separator; Pilot microbial electrochemical system (MES); Separate plug-in module architecture

Mesh:

Substances:

Year:  2019        PMID: 30856521     DOI: 10.1016/j.watres.2019.01.062

Source DB:  PubMed          Journal:  Water Res        ISSN: 0043-1354            Impact factor:   11.236


  4 in total

1.  Simultaneous removal of organic matter and nitrogen compounds by partitioned aeration in a 226 L-scale microbial fuel cell.

Authors:  Taiki Yamane; Naoko Yoshida; Mari Sugioka
Journal:  RSC Adv       Date:  2022-05-18       Impact factor: 4.036

2.  Estimation of total energy requirement for sewage treatment by a microbial fuel cell with a one-meter air-cathode assuming Michaelis-Menten COD degradation.

Authors:  Taiki Yamane; Naoko Yoshida; Mari Sugioka
Journal:  RSC Adv       Date:  2021-06-04       Impact factor: 4.036

3.  Effect of Contact Area and Shape of Anode Current Collectors on Bacterial Community Structure in Microbial Fuel Cells.

Authors:  Agathe Paitier; Naoufel Haddour; Chantal Gondran; Timothy M Vogel
Journal:  Molecules       Date:  2022-03-30       Impact factor: 4.411

4.  Electrochemistry-stimulated environmental bioremediation: Development of applicable modular electrode and system scale-up.

Authors:  Ai-Jie Wang; Hong-Cheng Wang; Hao-Yi Cheng; Bin Liang; Wen-Zong Liu; Jing-Long Han; Bo Zhang; Shu-Sen Wang
Journal:  Environ Sci Ecotechnol       Date:  2020-06-26
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.