Literature DB >> 30854817

[Influence of three-wall osseous defects on periodontal ligament stress with three-dimensional finite element analysis].

Shuang Wang1, Jiang Sun1, Yan-Yun Yu2.   

Abstract

OBJECTIVE: This study aims to explore the influence of three-wall osseous defects on periodontal ligament stress under normal occlusal forces.
METHODS: A finite element model for mandibular total dentition, periodontal ligament and alveolar bone was created based on cone beam computed tomography (CBCT) DICOM images. Mesial or distal proximal three-wall osseous defects at varying depths (namely, 1/3, 2/3 and 3/3 of the root) were simulated by modifying the elastic modulus of elements within the defects area. Occlusal forces with an angle of 45° to the long axis of the tooth were applied to the finite element model. In addition, the equivalent stresses of the periodontal ligament were analysed.
RESULTS: In the case of no bone defect, the mean value of the periodontal ligament equivalent stress of 14 teeth was 5.71 MPa. The equivalent stresses of the periodontal ligament at different depths (namely, 1/3, 2/3 and 3/3 of the root) were 6.61, 7.14 and 7.42 MPa, respectively. With increasing depth of the osseous defects, stress on the periodontal ligament increased considerably, and the initial stress increment was greater than that of a later stage. Periodontal ligament stresses with mesial proximal three-wall osseous defects (at depths of 1/3, 2/3 and 3/3 of the root) were 6.62, 7.19 and 7.51 MPa respectively. Periodontal ligament stresses with distal proximal three-wall osseous defects (at depths of 1/3, 2/3 and 3/3 of the root) were 6.60, 7.10 and 7.33 MPa, respectively. For three-wall osseous defects located in the mesial surface and distal surface, a significant difference in periodontal ligament stress was lacking. In the case of the same absorption depth, the size relationship of periodontal ligament stress was in the following order: premolars>molars>incisors>canines.
CONCLUSIONS: Shallow three-wall osseous defects will likely cause a notable loss in strength of the periodontal ligament. Therefore, teeth with three-wall osseous defects should become the focus of clinical research. Treatment for these teeth should be administered as early as possible.

Entities:  

Keywords:  periodontal ligament; stress; three-wall osseous defects; vertical bone defects

Mesh:

Year:  2019        PMID: 30854817      PMCID: PMC7030744          DOI: 10.7518/hxkq.2019.01.008

Source DB:  PubMed          Journal:  Hua Xi Kou Qiang Yi Xue Za Zhi        ISSN: 1000-1182


  6 in total

1.  [Effect of bite force on the periodontal tissue remodeling of molar with different levels of periodontal attachment ment].

Authors:  Yanfang Zhao; Weifeng Wang; Haitao Xin; Pei Miao; Yulu Wu
Journal:  Hua Xi Kou Qiang Yi Xue Za Zhi       Date:  2013-06

2.  2D and 3D finite element analysis of central incisor generated by computerized tomography.

Authors:  Isis A V P Poiate; Adalberto B Vasconcellos; Matsuyoshi Mori; Edgard Poiate
Journal:  Comput Methods Programs Biomed       Date:  2011-05-04       Impact factor: 5.428

3.  [Finite element analysis of periodontal tissue stress distribution of labial inverted impacted maxillary central incisor].

Authors:  Hui Jifang; Zhang Han; Qu Xiaodong; Yan Weijun; Shao Ping
Journal:  Hua Xi Kou Qiang Yi Xue Za Zhi       Date:  2015-02

4.  Three-dimensional modeling and finite element analysis in treatment planning for orthodontic tooth movement.

Authors:  Hussein H Ammar; Peter Ngan; Richard J Crout; Victor H Mucino; Osama M Mukdadi
Journal:  Am J Orthod Dentofacial Orthop       Date:  2011-01       Impact factor: 2.650

5.  Viscoelasticity of periodontal ligament: an analytical model.

Authors:  Sergei M Bosiakov; Anna A Koroleva; Sergei V Rogosin; Vadim V Silberschmidt
Journal:  Mech Adv Mater Mod Process       Date:  2015-11-16

6.  Inclusion of periodontal ligament fibres in mandibular finite element models leads to an increase in alveolar bone strains.

Authors:  Steven W McCormack; Ulrich Witzel; Peter J Watson; Michael J Fagan; Flora Gröning
Journal:  PLoS One       Date:  2017-11-30       Impact factor: 3.240

  6 in total