Literature DB >> 30848241

Comparison of clinical assessment and multifrequency bioimpedance analysis as methods of estimating volume status in peritoneal dialysis patients - A single-center experience
.

Bozidar Vujicic, Gordan Dorcic, Vesna Babic, Anamarija Rundic, Bosiljka Devcic, Daniel Victor Simac, Luka Zaputovic, Sanjin Racki.   

Abstract

INTRODUCTION: Clinical assessment (CA) is frequently used for the evaluation of volume status in peritoneal dialysis (PD) patients despite its subjectivity. Multiple-frequency bioelectrical impedance analysis (MF-BIA) is objective, accurate, and quick, proving to be a promising technique for measuring volume status. The aim of this study was to assess volume status in PD patients using CA and MF-BIA and to compare results.
MATERIALS AND METHODS: Incident PD patients were prospectively analyzed between January 1, 2014, and January 1, 2016, at the Clinical Hospital Center of -Rijeka, Croatia. Volume status measurements were performed once a month for 6 consecutive months. The presence of symptoms and signs associated with hyper- or hypovolemia were detected by CA. Euvolemia was defined as a symptom-free state or up to 2 symptoms maximum. Patients lacking up to 1.2 L of volume or with up to 1.2 L in excess were considered euvolemic, as measured by MF-BIA.
RESULTS: A total of 45 PD patients were analyzed; 51% were men, 27% were diabetic, the mean age was 52 ± 26 years, and PD duration was 11.5 ± 6.5 months. In comparison to MF-BIA, CA showed a significant difference in detected hypervolemia between baseline and follow-up (p = 0.708 vs. p = 0.01, respectively) and among all measurements (p < 0.01). Contrary to CA, volume status measured by MF-BIA correlated significantly with systolic and diastolic blood pressure (R = 0.29; p ≤ 0.01 and R = 0.26; p ≤ 0.01, respectively). CA showed low sensitivity (0.24) and high specificity (0.92) in detecting hypervolemia.
CONCLUSION: MF-BIA is an effective, objective, and safe method for assessing volume status in PD patients. Longitudinal monitoring of body composition changes - including hydration state - leading to adequate therapeutic intervention is a promising and potential application of MF-BIA along with CA.

Entities:  

Mesh:

Year:  2019        PMID: 30848241     DOI: 10.5414/CN109158

Source DB:  PubMed          Journal:  Clin Nephrol        ISSN: 0301-0430            Impact factor:   0.975


  1 in total

1.  Preoperative Phase Angle as a Risk Indicator in Cardiac Surgery-A Prospective Observational Study.

Authors:  Sylvia Ryz; Larissa Nixdorf; Jürgen Puchinger; Andrea Lassnigg; Dominik Wiedemann; Martin H Bernardi
Journal:  Nutrients       Date:  2022-06-16       Impact factor: 6.706

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.