Swati G Patel1, Anna Duloy2, Tonya Kaltenbach3, Matt Hall4, Charles Kahi5, Heiko Pohl6, Amit Rastogi7, Hazem Hammad1, Roy Soetikno8, Amandeep Shergill3, Violette Simon9, Tiffany Nguyen3, Eze Ezekwe9, Tara Ahi3, Rajesh N Keswani10, Sachin Wani9. 1. University of Colorado Anschutz Medical Center, Aurora, Colorado, USA; Rocky Mountain Regional Veterans Affairs Medical Center, Aurora, Colorado, USA. 2. University of Colorado Anschutz Medical Center, Aurora, Colorado, USA; Northwestern University, Chicago, Illinois, USA. 3. Veterans Affairs Medical Center, San Francisco, California, USA. 4. Children's Hospital Association, Lenexa, Kansas, USA. 5. Indiana University, Roudebush Veterans Affairs Medical Center, Indianapolis, Indiana, USA. 6. Veterans Affairs Medical Center, White River Junction, Vermont, USA. 7. University of Kansas, Kansas City, Kansas, USA. 8. Singapore General Hospital, Singapore, Singapore. 9. University of Colorado Anschutz Medical Center, Aurora, Colorado, USA. 10. Northwestern University, Chicago, Illinois, USA.
Abstract
BACKGROUND AND AIMS: Polyps <1 cm are the most commonly found polyps during colonoscopy. Cold snare removal is preferred given the significantly higher rate of incomplete resection associated with piecemeal biopsy forceps resection. There are currently no standardized tools to assess competence in cold snare polypectomy. This study aimed to develop and validate a cold snare polypectomy assessment tool (CSPAT). METHODS: Experts in cold snare polypectomy used a Delphi method to develop the CSPAT. Metrics with a greater than 85% agreement as being "important" or "very important" were included in the CSPAT. The tool included evaluation of polyp inspection, positioning, appropriate ensnarement of tissue to ensure a rim of normal tissue, tissue retrieval, and postpolypectomy site inspection. Experts in cold snare polypectomy used the CSPAT to evaluate preselected videos that were previously evaluated using the Direct Observation of Polypectomy Skills (DOPyS) tool. Interobserver agreement was evaluated. CSPAT scores were compared with DOPyS scores to assess content validity. RESULTS: Sixteen experts developed the 12-item CSPAT, and 13 experts reviewed 55 videos. There was a moderate degree of agreement in 10 metrics (κ = .52-.59) and a substantial degree of agreement (κ = .61-.63) in the other 2. There was a strong correlation between the mean of individual metrics 1 to 12 compared with the global competence assessment (ρ = .88, P < .001). There was a moderate correlation between the average overall DOPyS score and the overall CSPAT competence score (ρ = .56, P < .001). CONCLUSIONS: We have developed and validated a customized CSPAT that can be easily applied to video-based assessments to assess competence in training and among practicing endoscopists.
BACKGROUND AND AIMS: Polyps <1 cm are the most commonly found polyps during colonoscopy. Cold snare removal is preferred given the significantly higher rate of incomplete resection associated with piecemeal biopsy forceps resection. There are currently no standardized tools to assess competence in cold snare polypectomy. This study aimed to develop and validate a cold snare polypectomy assessment tool (CSPAT). METHODS: Experts in cold snare polypectomy used a Delphi method to develop the CSPAT. Metrics with a greater than 85% agreement as being "important" or "very important" were included in the CSPAT. The tool included evaluation of polyp inspection, positioning, appropriate ensnarement of tissue to ensure a rim of normal tissue, tissue retrieval, and postpolypectomy site inspection. Experts in cold snare polypectomy used the CSPAT to evaluate preselected videos that were previously evaluated using the Direct Observation of Polypectomy Skills (DOPyS) tool. Interobserver agreement was evaluated. CSPAT scores were compared with DOPyS scores to assess content validity. RESULTS: Sixteen experts developed the 12-item CSPAT, and 13 experts reviewed 55 videos. There was a moderate degree of agreement in 10 metrics (κ = .52-.59) and a substantial degree of agreement (κ = .61-.63) in the other 2. There was a strong correlation between the mean of individual metrics 1 to 12 compared with the global competence assessment (ρ = .88, P < .001). There was a moderate correlation between the average overall DOPyS score and the overall CSPAT competence score (ρ = .56, P < .001). CONCLUSIONS: We have developed and validated a customized CSPAT that can be easily applied to video-based assessments to assess competence in training and among practicing endoscopists.
Authors: Rayan Saade; Tyler Tsang; Michel Kmeid; David Miller; Zhiyan Fu; James Litynski; Patrick Young; Joseph C Anderson; Hwajeong Lee; Micheal Tadros Journal: Endosc Int Open Date: 2021-04-22
Authors: B Joseph Elmunzer; Catharine M Walsh; Gretchen Guiton; Jose Serrano; Amitabh Chak; Steven Edmundowicz; Richard S Kwon; Daniel Mullady; Georgios I Papachristou; Grace Elta; Todd H Baron; Patrick Yachimski; Evan L Fogel; Peter V Draganov; Jason R Taylor; James Scheiman; Vikesh K Singh; Shyam Varadarajulu; Field F Willingham; Gregory A Cote; Peter B Cotton; Violette Simon; Rebecca Spitzer; Rajesh Keswani; Sachin Wani Journal: Gastrointest Endosc Date: 2020-07-30 Impact factor: 9.427