Literature DB >> 30843462

Accuracy of Actigraph inclinometer to classify free-living postures and motion in adults with overweight and obesity.

Pedro B Júdice1, Luís Teixeira2, Analiza M Silva1, Luís B Sardinha1.   

Abstract

Sedentary behaviour (SB) is an independent health risk-factor and interrupting SB seems to be beneficial. SB is both defined by posture and intensity, thus objective measurement of postures remains a priority. The ActivPAL inclinometer (AP) has been used as a reference for postural estimation, but information on the validity of the Actigraph inclinometer (AGincl) is scarce. We compared postural estimation from waist-worn AGincl against thigh-worn AP, under free-living. Data from 10 participants (50.4 ± 11.4 years) were used and each 15s-block from 60-valid days was matched for the devices' comparison. At group level, no differences were found for SB and standing-time between inclinometers (p ≥ 0.05). AGincl underestimated stepping-time by 26.3 min and overestimated SB-to-upright transitions by 200.7 occasions (p < 0.05). Inter-individual variability was higher for SB and standing-time, and AGincl was in better agreement with AP for the stepping-time (area under the ROC curve = 0.98, with 100% sensitivity and 94% specificity; CCC = 0.44). These results highlight potential error in estimating individual postures using AGincl in overweight/obese adults and provide insights on the differences of using specific criteria on data-analysis. Our findings suggest that at the group level, AGincl provides similar estimates compared to AP for SB and standing-time, but not for SB-to-upright transitions or stepping-time. (ClinicalTrials.govID:NCT02007681).

Entities:  

Keywords:  ActivPAL (AP); Sedentary behaviour; objective methods; standing time; transitions

Mesh:

Year:  2019        PMID: 30843462     DOI: 10.1080/02640414.2019.1586281

Source DB:  PubMed          Journal:  J Sports Sci        ISSN: 0264-0414            Impact factor:   3.337


  3 in total

1.  A Temperature Independent Inclinometer Based on a Tapered Fiber Bragg Grating in a Fiber Ring Laser.

Authors:  Weihao Lin; Shengjie Zhou; Liyang Shao; Mang I Vai; Perry-Ping Shum; Weijie Xu; Fang Zhao; Feihong Yu; Yibin Liu; Yuhui Liu; Shuaiqi Liu
Journal:  Sensors (Basel)       Date:  2021-04-21       Impact factor: 3.576

Review 2.  Quality Evaluation of Free-living Validation Studies for the Assessment of 24-Hour Physical Behavior in Adults via Wearables: Systematic Review.

Authors:  Marco Giurgiu; Irina Timm; Marlissa Becker; Steffen Schmidt; Kathrin Wunsch; Rebecca Nissen; Denis Davidovski; Johannes B J Bussmann; Claudio R Nigg; Markus Reichert; Ulrich W Ebner-Priemer; Alexander Woll; Birte von Haaren-Mack
Journal:  JMIR Mhealth Uhealth       Date:  2022-06-09       Impact factor: 4.947

3.  Comparative assessment of ActiGraph data processing techniques for measuring sedentary behavior in adults with COPD.

Authors:  Katelyn E Webster; Natalie Colabianchi; Robert Ploutz-Snyder; Neha Gothe; Ellen Lavoie Smith; Janet L Larson
Journal:  Physiol Meas       Date:  2021-08-27       Impact factor: 2.688

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.