Large hospital variation in the utilization of Post-procedural CT to detect pulmonary embolism/Deep Vein Thrombosis in Patients Undergoing Total Knee or Hip Replacement Surgery: Japanese Nationwide Diagnosis Procedure Combination Database Study.

Kanako K Kumamaru1, Hiraku Kumamaru2, Hideo Yasunaga3, Hiroki Matsui3, Toshinobu Omiya4, Masaaki Hori1, Michimasa Suzuki1, Akihiko Wada1, Koji Kamagata1, Tomohiro Takamura1, Ryusuke Irie1, Atsushi Nakanishi1, Shigeki Aoki1.   

Abstract

OBJECTIVE: The purpose of the study was to investigate variation in the use of in-hospital CT for venous thromboembolism (VTE) detection after total knee or hip replacement (TKR/THR) among surgical patients, using a nationwide Japanese in-hospital administrative database.
METHODS: This retrospective study using a national administrative database (4/2012-3/2013) extracted patients who underwent TKR/THR surgeries at hospitals meeting the annual case-volume threshold of ≥ 30. Hospitals were categorized into three equally sized groups by frequency of postoperative CT use (low, middle, and high CT use group) to compare baseline patient-level and hospital-level characteristics. To further investigate between-hospital variation in CT usage, we fitted a hierarchical logistic regression model including hospital-specific random intercepts and fixed patient- and hospital-level effects. The intra class correlation coefficient was used to measure the amount of variability in CT use attributable to between-hospital variation.
RESULTS: A total of 39,127 patients discharged from 447 hospitals met the inclusion criteria. The median hospital stay was 25 days (interquartile range, 20 - 32) and 7,599 (19.4%) patients underwent CT for VTE. CT utilization varied greatly among the hospitals; the crude frequency ranged from 0 to 100 % (median, 7.3 %; interquartile range, 1.8 - 18.3 %). After adjustment for known hospital- and patient-level factors related to CT use, 47 % of the variation in CT use remained attributable to the behavior of individual hospitals.
CONCLUSION: We observed large inter hospital variability in the utilization of post-procedure CT for VTE detection in this Japanese TKR/THR cohort, suggesting that CT utilization is not optimized across the nation. ADVANCES IN KNOWLEDGE: We observed significant variability in the utilization of post-procedure CT for VTE detection among inpatients who underwent TKR/THR surgeries in a large sample of Japanese hospitals. The large variation suggests that CT utilization is not optimized across the nation, and that there may be potential overutilization of the technology in the highest CT use hospitals.

Entities:  

Mesh:

Year:  2019        PMID: 30835500      PMCID: PMC6580911          DOI: 10.1259/bjr.20180825

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  23 in total

1.  Effects of the per diem prospective payment system with DRG-like grouping system (DPC/PDPS) on resource usage and healthcare quality in Japan.

Authors:  Hironori Hamada; Miho Sekimoto; Yuichi Imanaka
Journal:  Health Policy       Date:  2012-01-23       Impact factor: 2.980

2.  The essence of the Japan Radiological Society/Japanese College of Radiology Imaging Guideline.

Authors:  Yasuyuki Yamashita; Sadayuki Murayama; Masahiro Okada; Yoshiyuki Watanabe; Masako Kataoka; Yasushi Kaji; Keiko Imamura; Yasuo Takehara; Hiromitsu Hayashi; Kazuko Ohno; Kazuo Awai; Toshinori Hirai; Kazuyuki Kojima; Shuji Sakai; Naofumi Matsunaga; Takamichi Murakami; Kengo Yoshimitsu; Toshifumi Gabata; Kenji Matsuzaki; Eriko Tohno; Yasuhiro Kawahara; Takeo Nakayama; Shuichi Monzawa; Satoru Takahashi
Journal:  Jpn J Radiol       Date:  2016-01       Impact factor: 2.374

Review 3.  Systematic review and meta-analysis of strategies for the diagnosis of suspected pulmonary embolism.

Authors:  Pierre-Marie Roy; Isabelle Colombet; Pierre Durieux; Gilles Chatellier; Hervé Sors; Guy Meyer
Journal:  BMJ       Date:  2005-07-30

4.  The validity of ICD-9-CM codes in identifying postoperative deep vein thrombosis and pulmonary embolism.

Authors:  Chunliu Zhan; James Battles; Yen-Pin Chiang; David Hunt
Journal:  Jt Comm J Qual Patient Saf       Date:  2007-06

Review 5.  A systematic review of validated methods for identifying venous thromboembolism using administrative and claims data.

Authors:  Leonardo Tamariz; Thomas Harkins; Vinit Nair
Journal:  Pharmacoepidemiol Drug Saf       Date:  2012-01       Impact factor: 2.890

6.  A new method of classifying prognostic comorbidity in longitudinal studies: development and validation.

Authors:  M E Charlson; P Pompei; K L Ales; C R MacKenzie
Journal:  J Chronic Dis       Date:  1987

7.  Outcomes after laparoscopic or open distal gastrectomy for early-stage gastric cancer: a propensity-matched analysis.

Authors:  Hideo Yasunaga; Hiromasa Horiguchi; Kazuaki Kuwabara; Shinya Matsuda; Kiyohide Fushimi; Hideki Hashimoto; John Z Ayanian
Journal:  Ann Surg       Date:  2013-04       Impact factor: 12.969

8.  Appropriate imaging utilization in Japan: a survey of accredited radiology training hospitals.

Authors:  Kanako K Kumamaru; Sadayuki Murayama; Yasuyuki Yamashita; Takeshi Nojo; Yoshiyuki Watanabe; Mariko Goto; Eriko Maeda; Junko Echigo; Shigeyoshi Soga; Shinya Fujii; Yutaka Tanami; Tetsuhiko Okabe; Masahiro Okada; Jiro Munechika; Hideki Ota; Mototaka Miyake; Hiroshi Honda; Shigeki Aoki
Journal:  Jpn J Radiol       Date:  2017-09-15       Impact factor: 2.374

9.  CT pulmonary angiography: a comparative analysis of the utilization patterns in emergency department and hospitalized patients between 1998 and 2003.

Authors:  J David Prologo; Robert C Gilkeson; Mireya Diaz; Joe Asaad
Journal:  AJR Am J Roentgenol       Date:  2004-10       Impact factor: 3.959

10.  Symptomatic pulmonary embolus after joint arthroplasty: stratification of risk factors.

Authors:  Javad Parvizi; Ronald Huang; Ibrahim J Raphael; William V Arnold; Richard H Rothman
Journal:  Clin Orthop Relat Res       Date:  2013-11-22       Impact factor: 4.176

View more
  1 in total

1.  Risk factors related to perioperative systemic complications and mortality in elderly patients with osteoporotic vertebral fractures-analysis of a large national inpatient database.

Authors:  Shingo Morishita; Toshitaka Yoshii; Atsushi Okawa; Hiroyuki Inose; Takashi Hirai; Masato Yuasa; Kiyohide Fushimi; Takeo Fujiwara
Journal:  J Orthop Surg Res       Date:  2020-11-10       Impact factor: 2.359

  1 in total