Literature DB >> 30831717

An x-band continuous wave saturation recovery electron paramagnetic resonance spectrometer based on an arbitrary waveform generator.

Joseph E McPeak1, Richard W Quine2, Sandra S Eaton1, Gareth R Eaton1.   

Abstract

An X-band (ca. 9-10 GHz) continuous wave saturation recovery spectrometer to measure electron spin-lattice relaxation (T1) was designed around an arbitrary waveform generator (AWG). The AWG is the microwave source and is used for timing of microwave pulses, generation of control signals, and digitizer triggering. Use of the AWG substantially simplifies the hardware in the bridge relative to that in conventional spectrometers and decreases the footprint. The bridge includes selectable paths with different power amplifications to permit experiments requiring hundreds of milliwatts to fractions of nanowatts for the pump and observe periods. The signal is detected with either a single or quadrature-output double balanced mixer. The system can operate with reflection or crossed-loop resonators. The source noise from the AWG was decreased by addition of a Wenzel high-stability clock. The source is sufficiently stable that automatic frequency control is not needed. The spectrometer was tested with samples that contained 1 × 1015 to 8 × 1017 spins and have T1 between a few hundred ns and hundreds of μs. Excellent signal-to-noise ratio was obtained with acquisition times of 2-90 s. Signal-to-noise performance is similar to that of a conventional saturation recovery spectrometer with a solid-state source. The stability and data reproducibility are better than with conventional sources. With replacement of frequency-sensitive components, this spectrometer can be used to perform saturation recovery measurements at any frequency within the range of the AWG.

Year:  2019        PMID: 30831717      PMCID: PMC6364795          DOI: 10.1063/1.5043316

Source DB:  PubMed          Journal:  Rev Sci Instrum        ISSN: 0034-6748            Impact factor:   1.523


  2 in total

1.  13C isotope enrichment of the central trityl carbon decreases fluid solution electron spin relaxation times.

Authors:  Whylder Moore; Joseph E McPeak; Martin Poncelet; Benoit Driesschaert; Sandra S Eaton; Gareth R Eaton
Journal:  J Magn Reson       Date:  2020-07-28       Impact factor: 2.229

Review 2.  EPR Everywhere.

Authors:  Joshua R Biller; Joseph E McPeak
Journal:  Appl Magn Reson       Date:  2021-01-24       Impact factor: 0.831

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.