Literature DB >> 30826230

Diagnostic Value of 3-Dimensional Vena Contracta Area for the Quantification of Residual Mitral Regurgitation After MitraClip Procedure.

Eleonora Avenatti1, G Burkhard Mackensen2, Kinan Carlos El-Tallawi1, Mark Reisman3, Lara Gruye2, Colin M Barker1, Stephen H Little4.   

Abstract

OBJECTIVES: The authors sought to define the feasibility and performance of 3-dimensional (3D) vena contracta area (VCA) measurement in evaluating total residual mitral regurgitation (MR) following percutaneous edge-to-edge clip (E-EC) mitral valve repair.
BACKGROUND: Residual MR severity after percutaneous repair is not only a determinant of procedural success, but also a major prognostic factor. To date, no single echocardiographic method has been recommended for post-procedural MR quantification, with the evaluation currently relying on a complex, multiparametric appraisal.
METHOD: The authors performed a retrospective study of patients undergoing the E-EC procedure, for which baseline and post-repair 3D color Doppler transesophageal echocardiogram datasets were available. Total VCA was recorded as the sum of individual VCAs (if more than 1) and compared with an expert multiparametric appraisal of MR severity as the reference standard. Receiver-operating characteristic analysis was performed.
RESULTS: 155 patient studies were available for review. Total VCA correlated with hemodynamic parameters and was significantly reduced after E-EC. Receiver-operating characteristic analysis demonstrated a VCA threshold of 0.27 cm2 for identification of ≥moderate MR, with good diagnostic accuracy (area under the curve 0.81) and a negative predictive value of 92%. Smaller VCA was associated with clinical New York Heart Association functional class improvement at 30-day follow-up.
CONCLUSIONS: Measurement of VCA is feasible using 3D color Doppler transesophageal echocardiography and provides reliable quantification of MR following E-EC transcatheter mitral valve repair.
Copyright © 2019 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  3D echocardiography; intraprocedural echocardiography; mitral regurgitation; transcatheter mitral repair; vena contracta area

Mesh:

Year:  2019        PMID: 30826230     DOI: 10.1016/j.jcin.2018.12.006

Source DB:  PubMed          Journal:  JACC Cardiovasc Interv        ISSN: 1936-8798            Impact factor:   11.195


  7 in total

1.  [Evaluation of mitral regurgitation : How much quantification do we need?]

Authors:  F Kreidel; T Ruf; A Tamm; M Geyer; T Emrich; R S von Bardeleben
Journal:  Herz       Date:  2019-11       Impact factor: 1.443

2.  Correlation of Intraprocedural and Follow Up Parameters for Mitral Regurgitation Grading after Percutaneous Edge-to-Edge Repair.

Authors:  Eduardo Pozo Osinalde; Alejandra Salinas Gallegos; Ximena Gordillo; Luis Nombela Franco; Pedro Marcos-Alberca; Patricia Mahía; Gabriela Tirado-Conte; José Juan Gómez de Diego; Pilar Jiménez Quevedo; Antonio Fernández-Ortíz; Julián Pérez-Villacastín; Jose Alberto de Agustín Loeches
Journal:  J Clin Med       Date:  2022-04-19       Impact factor: 4.964

Review 3.  Percutaneous Mitral Valve Repair: Multi-Modality Cardiac Imaging for Patient Selection and Intra-Procedural Guidance.

Authors:  Omar K Khalique; Rebecca T Hahn
Journal:  Front Cardiovasc Med       Date:  2019-09-20

4.  Automatic Assessment of Mitral Regurgitation Severity Using the Mask R-CNN Algorithm with Color Doppler Echocardiography Images.

Authors:  Qinglu Zhang; Yuanqin Liu; Jia Mi; Xing Wang; Xia Liu; Fenfen Zhao; Cuihuan Xie; Peipei Cui; Qingling Zhang; Xiangming Zhu
Journal:  Comput Math Methods Med       Date:  2021-09-13       Impact factor: 2.238

Review 5.  Role of 3D Transesophageal Echocardiography for Transcatheter Mitral Valve Repair-A Mini Review.

Authors:  Kensuke Hirasawa; Masaki Izumo
Journal:  Front Cardiovasc Med       Date:  2022-02-02

Review 6.  Complications of the Percutaneous Mitral Valve Edge-To-Edge Repair: Role of Transesophageal Echocardiography.

Authors:  Guisela Flores; Dolores Mesa; Soledad Ojeda; Javier Suárez de Lezo; Rafael Gonzalez-Manzanares; Guillermo Dueñas; Manuel Pan
Journal:  J Clin Med       Date:  2022-08-14       Impact factor: 4.964

Review 7.  State-of-the-art intra-procedural imaging for the mitral and tricuspid PASCAL Repair System.

Authors:  Rebecca T Hahn; Susheel K Kodali
Journal:  Eur Heart J Cardiovasc Imaging       Date:  2022-02-22       Impact factor: 6.875

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.