Is small cusp size a limitation for aortic valve repair?†.

Tatsuhiko Komiya1, Takeshi Shimamoto1, Michihito Nonaka1, Takehiko Matsuo1.   

Abstract

OBJECTIVES: We sought to investigate cusp size limitations for valve repair in patients with aortic regurgitation (AR).
METHODS: Preoperative computed tomography was performed in 105 patients. Cusp geometric height (GH) and annulus size were measured. Mean patient age was 60.7 ± 13.7 years. Mean GH of 3 cusps was used in the analysis. Annulus cusp mismatch was graded using predicted coaptation length. Patients were categorized by mean GH into group S (GH <16 mm; n = 35) or L (GH ≥16 mm; n = 70).
RESULTS: Preoperative mean GH was 17.1 ± 2.3 mm. GH and body height were significantly correlated (r = 0.61). Intraoperative mean GH (18.8 ± 2.2 mm) was larger than preoperative mean GH (P < 0.0001). However, postoperative (17.1 ± 2.0 mm) and preoperative mean GH did not differ. Moderate AR was not present on predischarge echocardiography. Mild AR was observed in 51% and 17% of patients in groups S and L, respectively (P = 0.006). During follow-up, moderate or severe AR was observed in 14% and 10% of patients in groups S and L, respectively (P = 0.74). Two patients in group S required reoperation for a regurgitant valve. Twenty (83%) and 15 (21%) patients in groups S and L, respectively, had severe annulus cusp mismatch before surgery. Annulus cusp mismatch resolved in most patients in group L postoperatively, whereas more than half the patients in group S still had severe mismatch.
CONCLUSIONS: Small cusp size (GH <16 mm) is not necessarily a contraindication in aortic valve repair. However, most patients in this group had annulus cusp mismatch. Root replacement or secure annulus plication is mandatory to correct annulus cusp mismatch.
© The Author(s) 2019. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

Entities:  

Keywords:  Annulus cusp mismatch; Aortic valve repair; Coaptation length; Computed tomography; Geometric height

Year:  2019        PMID: 30824918     DOI: 10.1093/ejcts/ezz053

Source DB:  PubMed          Journal:  Eur J Cardiothorac Surg        ISSN: 1010-7940            Impact factor:   4.191


  1 in total

Review 1.  Geometry of cusp and root determines aortic valve function.

Authors:  Shunsuke Matsushima; Irem Karliova; Simon Gauer; Shunsuke Miyahara; Hans-Joachim Schäfers
Journal:  Indian J Thorac Cardiovasc Surg       Date:  2019-04-06