| Literature DB >> 30820283 |
Abstract
PURPOSE: To review the management outcomes of black diaphragm intraocular (BDI) lens implantation in Arab patients with aniridia.Entities:
Keywords: Aniridia; Black Diaphragm Intraocular Lens Implantation; Visual Disturbances
Year: 2019 PMID: 30820283 PMCID: PMC6388531 DOI: 10.4103/jovr.jovr_244_17
Source DB: PubMed Journal: J Ophthalmic Vis Res ISSN: 2008-322X
Vision, refraction and ocular status before and at the last follow up after black diaphragm implantation in eyes with aniridia
| Number of eyes | Level | Before BDI implantation | After BDI implant | ||
|---|---|---|---|---|---|
| Uncorrected vision | 14 | Median | 20/400 | 20/100 | < 0.001* |
| 25% quartile | 20/400 | 20/125 | |||
| Minimum | Light perception | 20/600 | |||
| Maximum | 20/100 | 20/50 | |||
| Best corrected vision | 7 before and 14 after implantation | Median | 20/50 | 20/30 | < 0.001* |
| 25% quartile | 20/80 | 20/40 | |||
| Minimum | 20/125 | 20/100 | |||
| Maximum | 20/30 | 20/20 | |||
| Intraocular pressure | 14 | Mean | 18.6 | 17.8 | 0.002* |
| Standard deviation | 5.3 | 2.1 | |||
| Refractive error (spherical) | 14 | Median | 8.0 | −0.15 | < 0.001* |
| 25% quartile | 5.5 | −1.0 | |||
| Minimum | 0.0 | −2.0 | |||
| Maximum | 24.0 | 0.0 | |||
| Refractive error (cylinder) | 8 | Median | −3.0 | −0.7 | < 0.001* |
| 25% quartile | −4.0 | −1.0 | |||
| Minimum | −8.0 | −7.5 | |||
| Maximum | 0.0 | 0.0 | |||
| Glaucoma medications | 14 | 0 | 4 | 14 | < 0.001* |
| 1 | 10 | 0 |
BDI, black iris diaphragm, *P<0.05 is statistically significant
Management outcomes of late postoperative complications of black diaphragm implantation for aniridia
| Complication | Time of complication after BDI implant (months) | Vision before management | Surgery | Vision after surgery | Duration of follow up after surgery (months) |
|---|---|---|---|---|---|
| Corneal decompensation | 6 | 20/300 (UCVA) | Penetrating Keratoplasty | 20/100 (UCVA) | 2 |
| failure of Graft done before BDI | 12 | 2/200 (UCVA) | Penetrating Keratoplasty | 20/50 (UCVA) | 12 |
| Subluxated IOL due to trauma | 36 | 20/80 (BCVA) | Re-suturing of IOL | 20/20 (BCVA) | 17 |
BDI, black diaphragm intraocular; IOL, intraocular lens; BCVA, best corrected visual acuity; UCVA, uncorrected visual acuity