Literature DB >> 3081979

The reproducibility of the respiratory responses to maximum exercise.

C S Garrard, C Emmons.   

Abstract

In order to investigate the reproducibility of maximum progressive exercise we studied 6 healthy volunteers twice a day for 3 nonconsecutive days. The average within-subject coefficients of variation for the maximal ventilatory and heart rate (HR) responses ranged from 3.8% for HR to 12% for minute ventilation (Ve) and anaerobic threshold. Three-way analysis of variance revealed no significant variations in exercise parameters for the group as a whole except for the carbon dioxide output (VCO2) and respiratory exchange ratio (R) which was significantly greater in the afternoon (p less than 0.05). This was attributed to dietary effects of carbohydrate loading upon VCO2 and was associated in 1 subject with a significant increase in Ve (p less than 0.01). In another subject, morning values of Ve were consistently and significantly (p less than 0.05) greater than the afternoon values which could only be attributed to increased effort as indicated by an increased oxygen uptake. Tests of resting pulmonary mechanics (FEV1, FVC, FRC, RAW) measured before each exercise procedure showed no significant diurnal or day-to-day variations. Results indicate that while the maximal responses to progressive exercise are generally reproducible and the first exercise procedure can usually be considered representative, diurnal variations in R, VCO2 and Ve may occur which can be best avoided on repeated testing by exercising subjects at a standardized time of day.

Entities:  

Mesh:

Substances:

Year:  1986        PMID: 3081979     DOI: 10.1159/000194865

Source DB:  PubMed          Journal:  Respiration        ISSN: 0025-7931            Impact factor:   3.580


  8 in total

1.  VO₂ underestimation using the Aquatrainer compared with facemask measurements: is it all in the ventilation?

Authors:  Victor Machado Reis
Journal:  Eur J Appl Physiol       Date:  2010-11-17       Impact factor: 3.078

Review 2.  Automated metabolic gas analysis systems: a review.

Authors:  D J Macfarlane
Journal:  Sports Med       Date:  2001       Impact factor: 11.136

3.  Bioharness(™) Multivariable Monitoring Device: Part. II: Reliability.

Authors:  James A Johnstone; Paul A Ford; Gerwyn Hughes; Tim Watson; Andrew T Garrett
Journal:  J Sports Sci Med       Date:  2012-09-01       Impact factor: 2.988

4.  Exponential protocols for cardiopulmonary exercise testing on treadmill and cycle ergometer.

Authors:  J P Jamison; J Megarry; M Riley
Journal:  Eur J Appl Physiol       Date:  2009-09-22       Impact factor: 3.078

5.  Reproducibility of incremental maximal cycle ergometer testing in patients with restrictive lung disease.

Authors:  D D Marciniuk; R E Watts; C G Gallagher
Journal:  Thorax       Date:  1993-09       Impact factor: 9.139

6.  Comparison of peak cardiopulmonary performance parameters on a robotics-assisted tilt table, a cycle and a treadmill.

Authors:  Jittima Saengsuwan; Tobias Nef; Marco Laubacher; Kenneth J Hunt
Journal:  PLoS One       Date:  2015-04-10       Impact factor: 3.240

7.  Submaximal cardiopulmonary thresholds on a robotics-assisted tilt table, a cycle and a treadmill: a comparative analysis.

Authors:  Jittima Saengsuwan; Tobias Nef; Marco Laubacher; Kenneth J Hunt
Journal:  Biomed Eng Online       Date:  2015-11-10       Impact factor: 2.819

8.  Cardiopulmonary exercise testing early after stroke using feedback-controlled robotics-assisted treadmill exercise: test-retest reliability and repeatability.

Authors:  Oliver Stoller; Eling D de Bruin; Matthias Schindelholz; Corina Schuster-Amft; Rob A de Bie; Kenneth J Hunt
Journal:  J Neuroeng Rehabil       Date:  2014-10-11       Impact factor: 4.262

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.