Literature DB >> 30819629

Pre-contact lens and pre-corneal tear film kinetics.

Michel Guillon1, Kathryn Dumbleton, Panagiotis Theodoratos2, Kishan Patel2, Ruchi Gupta2, Trisha Patel2.   

Abstract

PURPOSE: Contact lenses (CL) insulate the corneal surface from the environment. It is possible that they influence the corneal sensory mechanism that contribute to spontaneous blinking. The study objective was to quantify the pre-CL and pre-corneal tear film kinetics (TFK) over blink period.
METHODS: The study population was 202 soft CL wearers, 133 non-lens wearers. TFK were quantified via post-hoc masked analysis of HD Tearscope videos. The parameters were: Non-Invasive Break Up Time (NIBUT), Exposed Area % at initial break (EA 1st Break) and at blink (EA Blink), Interblink period (IB), Protective Index (PI) and exposure speed of surface dehydration (ES mm2/s). The TFK of CL wearers were compared to non-lens wearers. The hypothesis was that pre-CL TFK was inferior to pre-corneal, specifically greater tear film anomalies presence at blink.
RESULTS: The pre-corneal NIBUT was longer than pre-CL NIBUT (9.1 vs. 5.1s, p < 0.001). The EA 1st Break was smaller for pre-corneal than pre-CL (0.003 vs. 0.43%, p < 0.001). The mean IB time was similar for pre-CL and pre-corneal (9.4 vs. 9.8s, p = 0.213). The EA Blink % was smaller for pre-corneal than pre-CL (0.03 vs. 6.66%, p < 0.001). The ES was faster for pre-CL than pre-corneal (0.339 vs. 0.004, p < 0.001). The PI was greater for pre-corneal than pre-CL (99.9 vs. 97.1%, p < 0.001).
CONCLUSIONS: Pre-CL TFK were significantly inferior than pre-corneal, confirmed the hypothesis. The NIBUT was shorter. Once the initial break occurred, ES was faster, and EA was much greater for pre-CL than pre-corneal. The differences identified may be an aetiological component of CL discomfort and the relationship between TFK and discomfort in contact lens wearers should be investigated.
Copyright © 2019 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Blink; Contact lens wearers; Exposed area; NIBUT; Non wearers; Protective index; Tear film kinetics

Mesh:

Year:  2019        PMID: 30819629     DOI: 10.1016/j.clae.2019.02.001

Source DB:  PubMed          Journal:  Cont Lens Anterior Eye        ISSN: 1367-0484            Impact factor:   3.077


  3 in total

1.  Orthokeratology Lens Wear for 2 Years in Children Did Not Alter Tear Film Lipid Thickness by Non-Invasive Interferometry.

Authors:  Haozhe Yu; Yifei Yuan; Wenyu Wu; Weizhen Zeng; Louis Tong; Yu Zhang; Yun Feng
Journal:  Front Med (Lausanne)       Date:  2022-02-10

2.  Dry eye disease and tear film assessment through a novel non-invasive ocular surface analyzer: The OSA protocol.

Authors:  María Carmen Sánchez-González; Raúl Capote-Puente; Marta-C García-Romera; Concepción De-Hita-Cantalejo; María-José Bautista-Llamas; Carmen Silva-Viguera; José-María Sánchez-González
Journal:  Front Med (Lausanne)       Date:  2022-08-10

3.  Comparison of the Pre-Lens Tear Film Stability and Visual Performance of a Novel and Two Other Daily Disposable Contact Lenses in Healthcare Professionals Wearing Facial Masks for Prolonged Time.

Authors:  Aysegul Penbe; Hatice Selen Kanar; Raziye Donmez Gun
Journal:  Clin Optom (Auckl)       Date:  2022-10-10
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.