Literature DB >> 30816361

Use of the Patent Blue and Air in the Preoperative Marking of Impalpable Breast Lesions.

Walberto Monteiro Neiva Eulálio Filho1, Antônio Marques de Medeiros Neto1, Rodolfo Myronn de Melo Rodrigues1, Araci Castelo Branco Rodrigues Alves1, Sabas Carlos Vieira1.   

Abstract

OBJECTIVE: The goal of this study is to analyze the applicability of the patent blue dye and air in the preoperative marking of impalpable mammary lesions with indication of surgical resection.
MATERIALS AND METHODS: A prospective cohort study was performed. We selected 49 patients with detection of impalpable lesions on a breast mammography or breast ultrasonography. The patients received the dye injection as close to their surgery time as possible. The criteria analyzed included: 1) complete marking and identification of the lesion; 2) complete removal of the lesion; 3) in cases of malignant lesions, presence of free margins for successful surgery; 4) occurrence of allergic events; 5) necessity of reoperation; and 6) difficulty in locating lesions.
RESULTS: All lesions were marked, and they were successfully excised. In cases of malignancy, free margins were obtained in 100% of the cases. There were no allergic events or reoperations. Only 8.9% of the lesions were difficult to locate.
CONCLUSION: The marking with patent blue and air is an effective alternative for the labeling of impalpable breast lesions, and it has satisfactory surgical oncology results. All lesions were resected, 91.1% of them were performed with no difficulties, and free margins were obtained in 100% of cases of malignancy.

Entities:  

Keywords:  Breast neoplasms; biopsy; coloring agents; mammography; patent blue

Year:  2018        PMID: 30816361      PMCID: PMC6385726          DOI: 10.5152/ejbh.2018.4321

Source DB:  PubMed          Journal:  Eur J Breast Health


  11 in total

1.  Anaphylaxis to patent blue dye during sentinel lymph node biopsy for breast cancer.

Authors:  M H Mullan; S J Deacock; N F Quiney; M W Kissin
Journal:  Eur J Surg Oncol       Date:  2001-03       Impact factor: 4.424

2.  Radioguided excision of the nonpalpable breast cancer and simultaneous sentinel lymphnode biopsy using a single radiopharmaceutical: an original approach to accurate administration of the blue dye.

Authors:  Janez Zgajnar; Nikola Besic; Snjezana Frković-Grazio; Marko Hocevar; Barbara Vidergar; Miljeva Rener; Jurij Lindtner
Journal:  J Surg Oncol       Date:  2003-05       Impact factor: 3.454

3.  Localization of nonpalpable breast lesions using hook-wire combined with isosulfan blue dye.

Authors:  George C Zografos; Carmen Doumitriou; Dimitrios Lappas; George Karatzikos; Emi Bami; Costas Fotiadis; Evagelos Menenakos; George Androulakis
Journal:  J Surg Oncol       Date:  2003-01       Impact factor: 3.454

4.  PULMONARY AIR EMBOLISM.

Authors:  I MANDELBAUM; H KING
Journal:  Surg Forum       Date:  1963

5.  Radiocolloid in combination with methylene dye localization, rather than wire localization, is a preferred procedure for excisional biopsy of nonpalpable breast lesions.

Authors:  Jun Tang; Xiao-Ming Xie; Xi Wang; Ze-Ming Xie; Jie-Hua He; Yao-Pan Wu; Wei Fan; Jian-Hua Fu; Ming-Tian Yang
Journal:  Ann Surg Oncol       Date:  2010-08-03       Impact factor: 5.344

6.  Marking non-palpable breast masses with injected methylene blue dye, an easy, safe and low cost method for developing countries and resource-limited areas.

Authors:  Alavi Nasrinossadat; Fonooni Ladan; Ensani Fereshte; Olfatbakhsh Asieh; Chaman Reza; Sadjadian Akramossadat; Mehra Golshan
Journal:  Asian Pac J Cancer Prev       Date:  2011

7.  Significance of methylene blue dye for localization biopsy of nonpalpable breast lesions.

Authors:  Jun Tang; Xi Wang; Yao-Pan Wu; Xin Wang; Zhen-Qiang Lian; Jian-Hua Fu; Ming-Tian Yang
Journal:  Ai Zheng       Date:  2009-01-09

8.  Adverse reactions to patent blue V dye - The NEW START and ALMANAC experience.

Authors:  L Barthelmes; A Goyal; R G Newcombe; F McNeill; R E Mansel
Journal:  Eur J Surg Oncol       Date:  2009-11-24       Impact factor: 4.424

9.  Toluidine blue dye as a breast localization marker.

Authors:  D J Czarnecki; H K Feider; G F Splittgerber
Journal:  AJR Am J Roentgenol       Date:  1989-08       Impact factor: 3.959

10.  Patent blue and air as an alternative for resection of nonpalpable breast lesions: a case series.

Authors:  Sabas Carlos Vieira; Viviane Carvalho Alves; Tayná Cristinne Barros de Oliveira; Jacira Oliveira Ibiapina; Emmyle Cristyne Alves Soares; Marcus Luciano Lopes de Paiva Crisanto
Journal:  Sao Paulo Med J       Date:  2014       Impact factor: 1.044

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.