Literature DB >> 30813003

A nonenzymatic electrochemical glucose sensor based on molecularly imprinted polymer and its application in measuring saliva glucose.

Alassane Diouf1, Benachir Bouchikhi2, Nezha El Bari3.   

Abstract

Diabetes mellitus (DM) is often diagnosed by invasive or enzymatic methods being progressively somewhat undesirable. If salivary glucose (SG) level correlates with blood glucose (BG), it could be useful for early DM detection. In this work, a molecular imprinted polymer (MIP) approach was used to develop an electrochemical non-enzymatic sensor to determine SG in micro-molar levels. The MIP based Screen printed gold electrode (Au-SPE) was prepared by electropolymerizing Acrylamide/Bis-Acrylamide (AAM/NNMBA) in the presence of glucose (G) as a template. The Cyclic voltammetry (CV), differential pulse voltammetry (DPV) and electrochemical impedance spectroscopy (EIS) techniques were employed for the electrochemical measurements with Ferri/Ferrocyanide as redox probe in phosphate buffer saline. Morphological characterizations of the elaborated sensors were performed by using atomic force microscopy (AFM) and scanning electron microscopy coupled with energy dispersive X-ray spectroscopy (SEM-EDS). Important parameters influencing the MIP sensor performances such as extraction, incubation time, potential range and number of CV cycles, were studied and optimized. Under optimum conditions, the sensor could effectively detect glucose avoiding interferences of structural similar substances like lactose and sucrose. In a working range from 0.5 to 50 μg/mL, it exhibits a detection and quantification limits of 0.59 μg/mL and 1.9 μg/mL, respectively. Additionally, the real saliva glucose determination was compared to those of finger prick blood with satisfactory results (R2 = 0.99) by using partial least squares (PLS) statistical technique. Correspondingly, this work has demonstrated a cheap, simple and effective sensing platform for non-enzymatic glucose detection thus making it a promising tool for future evolution of accurate and reliable non-invasive DM diagnosis.
Copyright © 2019. Published by Elsevier B.V.

Entities:  

Keywords:  Electrochemical sensor; Glucometer; Molecular imprinted polymer; Non-enzymatic; Saliva glucose; Screen-printed gold electrode

Mesh:

Substances:

Year:  2019        PMID: 30813003     DOI: 10.1016/j.msec.2019.01.001

Source DB:  PubMed          Journal:  Mater Sci Eng C Mater Biol Appl        ISSN: 0928-4931            Impact factor:   7.328


  5 in total

Review 1.  Sense and Learn: Recent Advances in Wearable Sensing and Machine Learning for Blood Glucose Monitoring and Trend-Detection.

Authors:  Ahmad Yaser Alhaddad; Hussein Aly; Hoda Gad; Abdulaziz Al-Ali; Kishor Kumar Sadasivuni; John-John Cabibihan; Rayaz A Malik
Journal:  Front Bioeng Biotechnol       Date:  2022-05-12

2.  Waste eggshell membrane-templated synthesis of functional Cu2+-Cu+/biochar for an ultrasensitive electrochemical enzyme-free glucose sensor.

Authors:  Linzhi Li; Tianzeng Huang; Saijun He; Xing Liu; Qi Chen; Jian Chen; Hongmei Cao
Journal:  RSC Adv       Date:  2021-05-25       Impact factor: 4.036

Review 3.  Artificial Biomimetic Electrochemical Assemblies.

Authors:  Tanja Zidarič; Matjaž Finšgar; Uroš Maver; Tina Maver
Journal:  Biosensors (Basel)       Date:  2022-01-15

Review 4.  Carbon nanomaterial hybrids via laser writing for high-performance non-enzymatic electrochemical sensors: a critical review.

Authors:  Marcel Simsek; Nongnoot Wongkaew
Journal:  Anal Bioanal Chem       Date:  2021-05-12       Impact factor: 4.142

Review 5.  Progress of Polyaniline Glucose Sensors for Diabetes Mellitus Management Utilizing Enzymatic and Non-Enzymatic Detection.

Authors:  Velia Osuna; Alejandro Vega-Rios; Erasto Armando Zaragoza-Contreras; Iván Alziri Estrada-Moreno; Rocio B Dominguez
Journal:  Biosensors (Basel)       Date:  2022-02-22
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.