Literature DB >> 30807538

Development and Validation of a Fast Ultra-High Performance Liquid Chromatography-Fluorescent Method for the Quantification of Hydroxychloroquine and Its Metabolites in Patients With Lupus.

Gaëlle Noé1, Zahir Amoura2, David Combarel1, Lesli Lori1, Nadine Tissot1, Aguila Seycha1, Christian Funck-Brentano1,3, Noël Zahr1.   

Abstract

BACKGROUND: Hydroxychloroquine (HCQ) is approved for the treatment of systemic lupus erythematosus (SLE). Therapeutic drug monitoring of HCQ is necessary to detect nonadherence and to improve treatment efficacy in patients with SLE. Liquid chromatographic-tandem mass spectroscopy and high performance liquid chromatography (HPLC)-fluorescent methods are currently used to measure whole blood concentrations of HCQ and its 2 main metabolites desethylhydroxychloroquine and desethylchloroquine in patients with SLE. This study reports the development and validation of an ultra-HPLC (U-HPLC) method with fluorescence detection for the simultaneous quantification of HCQ and its metabolites in whole blood.
METHODS: After adding chloroquine (internal standard) to the samples, a single-step protein precipitation and a subsequent filtration were used for blood sample preparation. Analytes were separated under isocratic elution on a U-HPLC RP18 column with a total run time of 7 minutes. The mobile phase consisted of piperazine buffer (46.4 mM, pH = 9.8) and acetonitrile (68:32, vol/vol), which was delivered at a flow rate of 0.4 mL/min. Fluorescence excitation and emission wavelengths were 335 and 390 nm, respectively. Assay performance parameters were evaluated per FDA bioanalytical guidelines.
RESULTS: The calibration curve was linear from 125 to 4000 ng/mL for HCQ. The lower limit of quantification was 10 ng/mL for all analytes. For HCQ, desethylchloroquine, and desethylhydroxychloroquine, accuracies and imprecisions ranged from -7.90% to 7.85% and 1.14% to 8.78%, respectively.
CONCLUSIONS: A sensitive, accurate, and fast U-HPLC-fluorescent method was validated and successfully applied to quantify whole blood concentrations to perform therapeutic drug monitoring of HCQ in pediatric and adult lupus patients.

Entities:  

Mesh:

Substances:

Year:  2019        PMID: 30807538     DOI: 10.1097/FTD.0000000000000614

Source DB:  PubMed          Journal:  Ther Drug Monit        ISSN: 0163-4356            Impact factor:   3.681


  3 in total

1.  Hydroxychloroquine to Prevent Recurrent Congenital Heart Block in Fetuses of Anti-SSA/Ro-Positive Mothers.

Authors:  Peter Izmirly; Mimi Kim; Deborah M Friedman; Nathalie Costedoat-Chalumeau; Robert Clancy; Joshua A Copel; Colin K L Phoon; Bettina F Cuneo; Rebecca E Cohen; Kimberly Robins; Mala Masson; Benjamin J Wainwright; Noel Zahr; Amit Saxena; Jill P Buyon
Journal:  J Am Coll Cardiol       Date:  2020-07-21       Impact factor: 24.094

2.  Development and Validation of a Simple and Rapid Ultrahigh-Performance Liquid Chromatography Tandem Spectrometry Method for the Quantification of Hydroxychloroquine in Plasma and Blood Samples in the Emergency Context of SARS-CoV-2 Pandemic.

Authors:  Natalia Doudka; Madeleine Giocanti; Manon Basso; Renée Ugdonne; Karine Barthelemy; Bruno Lacarelle; Olivier Blin; Caroline Solas; Romain Guilhaumou
Journal:  Ther Drug Monit       Date:  2021-08-01       Impact factor: 3.681

3.  Evaluation of Hydroxychloroquine Blood Concentrations and Effects in Childhood-Onset Systemic Lupus Erythematosus.

Authors:  Noël Zahr; Saik Urien; Christian Funck-Brentano; Hélène Vantomme; Nicolas Garcelon; Isabelle Melki; Margaux Boistault; Olivia Boyer; Brigitte Bader-Meunier
Journal:  Pharmaceuticals (Basel)       Date:  2021-03-17
  3 in total