Device-induced platelet dysfunction in mechanically assisted circulation increases the risks of thrombosis and bleeding.

Zengsheng Chen1, Jiafeng Zhang1, Kafayat Kareem1, Douglas Tran1, Robert G Conway1, Katherin Arias1,2, Bartley P Griffith1, Zhongjun J Wu1,2.   

Abstract

Thrombotic and bleeding complications are the major obstacles for expanding mechanical circulatory support (MCS) beyond the current use. While providing the needed hemodynamic support, those devices can induce damage to blood, particularly to platelets. In this study, we investigated device-induced alteration of three major platelet surface receptors, von Willebrand factor (VWF) and associated hemostatic functions relevant to thrombosis and bleeding. Fresh human whole blood was circulated in an extracorporeal circuit with a clinical rotary blood pump (CentriMag, Abbott, Chicago, IL, USA) under the clinically relevant operating condition for 4 hours. Blood samples were examined every hour for glycoprotein (GP) IIb/IIIa activation and receptor loss of GPVI and GPIbα on the platelet surface with flow cytometry. Soluble P-selectin in hourly collected blood samples was measured by enzyme linked immunosorbent assay to characterize platelet activation. Adhesion of device-injured platelets to fibrinogen, collagen, and VWF was quantified with fluorescent microscopy. Device-induced damage to VWF was characterized with western blotting. The CentriMag blood pump induced progressive platelet activation with blood circulating time. Particularly, GPIIb/IIIa activation increased from 1.1% (Base) to 11% (4 hours) and soluble P-selectin concentration increased from 14.1 ng/mL (Base) to 26.5 ng/mL (4 hours). Those device-activated platelets exhibited increased adhesion capacity to fibrinogen. Concurrently, the CentriMag blood pump caused progressive platelet receptor loss (GPVI and GPIbα) with blood circulating time. Specifically, MFI of the GPVI and GPIbα receptors decreased by 17.2% and 16.1% for the 4-hours sample compared to the baseline samples, respectively. The device-injured platelets exhibited reduced adhesion capacities to collagen and VWF. The high molecular weight multimers (HMWM) of VWF in the blood disappeared within the first hour of the circulation. Thereafter the multimeric patterns of VWF were stable. The change in the VWF multimeric pattern was different from the progressive structural and functional changes of platelets with the circulation time. This study suggested that the CentriMag blood pump could induce two opposite effects on platelets and associated hemostatic functions under a clinically relevant operating condition. The device-altered hemostatic function may contribute to thrombosis and bleeding simultaneously as occurring in patients supported by a rotary blood pump. Device-induced damage of platelets may be an important cause for bleeding in patients supported with rotary blood pump MCS systems relative to device-induced loss of HMWM-VWF.
© 2019 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

Entities:  

Keywords:  continuous flow ventricular assist device; hemostasis dysfunction; high mechanical shear stress; platelet; von Willebrand factor

Mesh:

Substances:

Year:  2019        PMID: 30805954      PMCID: PMC6687529          DOI: 10.1111/aor.13445

Source DB:  PubMed          Journal:  Artif Organs        ISSN: 0160-564X            Impact factor:   3.094


  8 in total

Review 1.  The ongoing quest for the first total artificial heart as destination therapy.

Authors:  Annemijn Vis; Maziar Arfaee; Husain Khambati; Mark S Slaughter; Jan F Gummert; Johannes T B Overvelde; Jolanda Kluin
Journal:  Nat Rev Cardiol       Date:  2022-06-06       Impact factor: 32.419

2.  Association of Genetic Polymorphisms with Complications of Implanted LVAD Devices in Patients with Congestive Heart Failure: A Kazakhstani Study.

Authors:  Madina R Zhalbinova; Saule E Rakhimova; Ulan A Kozhamkulov; Gulbanu A Akilzhanova; Galina K Kaussova; Kenes R Akilzhanov; Yuriy V Pya; Joseph H Lee; Makhabbat S Bekbossynova; Ainur R Akilzhanova
Journal:  J Pers Med       Date:  2022-05-04

Review 3.  Shear-mediated platelet activation in the free flow II: Evolving mechanobiological mechanisms reveal an identifiable signature of activation and a bi-directional platelet dyscrasia with thrombotic and bleeding features.

Authors:  Yana Roka-Moiia; Kaitlyn R Ammann; Samuel Miller-Gutierrez; Alice Sweedo; Daniel Palomares; Joseph Italiano; Jawaad Sheriff; Danny Bluestein; Marvin J Slepian
Journal:  J Biomech       Date:  2021-04-27       Impact factor: 2.789

4.  Platelet Function During Extracorporeal Membrane Oxygenation in Adult Patients.

Authors:  Camilla Mains Balle; Anni Nørgaard Jeppesen; Steffen Christensen; Anne-Mette Hvas
Journal:  Front Cardiovasc Med       Date:  2019-08-08

Review 5.  Device-Induced Hemostatic Disorders in Mechanically Assisted Circulation.

Authors:  Shigang Wang; Bartley P Griffith; Zhongjun J Wu
Journal:  Clin Appl Thromb Hemost       Date:  2021 Jan-Dec       Impact factor: 2.389

6.  Flow Dynamics and Mixing in Extracorporeal Support: A Study of the Return Cannula.

Authors:  Julien Lemétayer; L Mikael Broman; Lisa Prahl Wittberg
Journal:  Front Bioeng Biotechnol       Date:  2021-02-10

7.  Mortality in cardiogenic shock patients receiving mechanical circulatory support: a network meta-analysis.

Authors:  Qun Zhang; Yu Han; Shukun Sun; Chuanxin Zhang; Han Liu; Bailu Wang; Shujian Wei
Journal:  BMC Cardiovasc Disord       Date:  2022-02-13       Impact factor: 2.298

8.  Validation of a Miniaturized Test Loop for the Assessment of Human Blood Damage by Continuous-Flow Left-Ventricular Assist Devices.

Authors:  Eva Woelke; Ilona Mager; Thomas Schmitz-Rode; Ulrich Steinseifer; Johanna C Clauser
Journal:  Ann Biomed Eng       Date:  2021-08-24       Impact factor: 3.934

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.