Automated online coupling of robot-assisted single drop microextraction and liquid chromatography.

Deyber Arley Vargas Medina1, Luis Felipe Rodríguez Cabal1, Guilherme Miola Titato1, Fernando Mauro Lanças1, Álvaro José Santos-Neto2.   

Abstract

A high-throughput and innovative setup has been developed to automate the online integration of single drop microextraction (SDME), liquid chromatography (LC) and high-resolution mass spectrometry (QqToF). SDME and LC were online hyphenated for the first time. SDME was carried out by a lab-made cartesian robot actuating a 100 μL syringe, equipped with a three-way solenoid microvalve that allowed the online transference of the enriched extract to the chromatographic system, through a six-port switching valve. The complete method, including the synchronized robot action, valves, and the analytical instruments, was controlled by an Arduino Mega board. The merits of the proposed setup were demonstrated by the triazines determination in coconut water samples. The most relevant extraction parameters, such as drop size, exposure time, stirring effect, salt addition and pH were systematically investigated. Under optimized conditions (60 μL drop volume and 10 min extraction time), the LC-UV enrichment factors (EF) and the extraction recoveries (ER) ranged between 15.2-18.4 and 11.4-13.8%, respectively. Using the SDME-LC-MS setup, the linear range, detection limit (S/N = 3) and precision (RSD, n = 6 at 0.25 μg L-1 level of concentration) were 0.25-25 μg L-1, 0.10 μg L-1 and 16.8% for simazine; 0.25-25 μg L-1, 0.05 μg L-1 and 14.7% for atrazine; and 0.25-25 μg L-1, 0.05 μg L-1 and 18.5% for propazine, respectively. Although none of the analytes were detected in the evaluated commercial samples, the results indicate that the proposed online SDME-LC setup is a competitive analytical strategy for the determination of target organic compounds in complex matrices.
Copyright © 2019 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Automation; Liquid chromatography; Mass spectrometry; Microextraction; Sample preparation

Mesh:

Substances:

Year:  2019        PMID: 30803786     DOI: 10.1016/j.chroma.2019.02.036

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  2 in total

1.  Application of ZnS/S/S-RGO three-component nanocomposites in dispersive solid-phase microextraction coupled with ion mobility spectrometry for ultra-trace determination  of multiclass pesticides.

Authors:  Sedigheh Rahmani; Behzad Aibaghi
Journal:  Mikrochim Acta       Date:  2021-12-04       Impact factor: 5.833

2.  A cartridge-based device for automated analyses of solid matrices by online sample prep-capillary LC-MS/MS.

Authors:  Edvaldo Vasconcelos Soares Maciel; Fernando Mauro Lanças
Journal:  Anal Bioanal Chem       Date:  2022-02-02       Impact factor: 4.142

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.