Literature DB >> 30799671

An Extremely Rare Complication: Abdominal Aortic Aneurysm Rupture Caused by Migration of a Zenith Main Body Years After Repair of the Suprarenal Stent Separation.

Tatsuo Ueda1, Hiroyuki Tajima2, Satoru Murata3, Kotomi Iwata1, Hidemasa Saitou1, Izumi Miki1, Daisuke Yasui1, Fumie Sugihara1, Shiro Onozawa4, Tetsuro Morota5, Shin-Ichiro Kumita1.   

Abstract

PURPOSE: To report an unusual case of an abdominal aortic aneurysm (AAA) rupture caused by migration of a Zenith stent-graft main body years after its separation from the suprarenal stent. CASE REPORT: A 72-year-old man underwent endovascular aneurysm repair with a Zenith stent-graft for an infrarenal AAA in year 2000. At that time, a femorofemoral bypass was performed because the left external iliac and common femoral arteries were dissected during treatment. In 2013, follow-up computed tomography (CT) showed disconnection of the uncovered proximal stent, which led to a type Ia endoleak. An additional Zenith main body and Large Palmaz XL balloon-expandable stent were deployed; the endoleak disappeared. In 2016, the patient had abdominal pain, and emergency CT showed AAA rupture caused by migration of the first main body deployed in 2000 under the distal edge of the contralateral (left) leg of the additional main body from 2013, which led to a type IIIa endoleak between the 2 main bodies. A converter and iliac legs were deployed to successfully seal the type IIIa endoleak. The patient remains well 18 months after the second repair; CT scans document stable stent-grafts and no endoleak.
CONCLUSION: Physicians should be aware of the potential risk for AAA rupture caused by late main body migration after treatment for suprarenal stent separation from a Zenith stent-graft.

Entities:  

Keywords:  abdominal aortic aneurysm rupture; complication; endograft; endoleak; endovascular aneurysm repair; migration; separation; stent-graft; suprarenal stent

Mesh:

Year:  2019        PMID: 30799671     DOI: 10.1177/1526602819830979

Source DB:  PubMed          Journal:  J Endovasc Ther        ISSN: 1526-6028            Impact factor:   3.487


  2 in total

1.  An unusual cause of failure in Zenith Alpha Abdominal endograft.

Authors:  Raffaella N Berchiolli; Michele Marconi; Irene Bargellini; Giulia Bertagna; Daniele Adami; Davide M Mocellin; Roberto Cioni; Mauro Ferrari; Nicola Troisi
Journal:  Eur J Med Res       Date:  2022-03-02       Impact factor: 4.981

2.  Repair of a late endoleak following complete proximal endograft fixation strut separation.

Authors:  Paul Ghaly; Jim Iliopoulos; Glen Schlaphoff; Mehtab Ahmad
Journal:  J Vasc Surg Cases Innov Tech       Date:  2021-04-14
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.