Literature DB >> 30797458

Quantum dot modified interface for electrochemical immunosensing of procalcitonin for the detection of urinary tract infection.

Aditya Sharma Ghrera1.   

Abstract

An electrochemical immunoelectrode is fabricated and investigated for quantification of the Procalcitonin (PCT), a protein over expressed in urinary tract infection (UTI). The sensor electrode is prepared by self assembling the conjugate of Zinc sulfide capped Cadmium selenide quantum dots (QD) and PCT specific monoclonal antibody (MAb) over the indium-tin-oxide (ITO) coated glass substrate. The presence of QD in the conjugate is found to provide more electroactive surface area and improved electron transfer kinetics and diffusion coefficient to the immunoelectrode. The electrochemical characteristics of this immunoelectrode towards synthetic PCT sample reveal specificity among the pool of various analytes. The sensing characteristics reveal that the sensor can potentially detect PCT over a concentration of 0.21 ng/mL which is above pathological range in healthy person. However, in absence of QD, the detection range lies in between 0.1 μg/mL to 10 μg/mL, which is far above the expressed concentration of PCT in UTI. Under optimal conditions, the QD based immunoelectrode exhibited good calibration range from 1 ng/ml to 10 μg/mL.
Copyright © 2019 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Cyclic voltammetry; Electrochemical sensor; Immunoelectrode; Procalcitonin; Quantum dot; Urinary tract infection

Mesh:

Substances:

Year:  2018        PMID: 30797458     DOI: 10.1016/j.aca.2018.12.047

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  3 in total

1.  Construction of efficient electrochemiluminescence resonance energy transfer sensor based on SnO2/SnS2QDs-Ru@IRMOF-3 composite for sensitive detection of procalcitonin.

Authors:  Dongmiao Qin; Shuo Meng; Yusheng Wu; Zhi Luo; Biyang Deng
Journal:  Mikrochim Acta       Date:  2022-10-21       Impact factor: 6.408

2.  Magnetic Bead-Based Electrochemical Immunoassays On-Drop and On-Chip for Procalcitonin Determination: Disposable Tools for Clinical Sepsis Diagnosis.

Authors:  Águeda Molinero-Fernández; María Moreno-Guzmán; Miguel Ángel López; Alberto Escarpa
Journal:  Biosensors (Basel)       Date:  2020-06-17

Review 3.  Micro- and nanosensors for detecting blood pathogens and biomarkers at different points of sepsis care.

Authors:  Alejandra Alba-Patiño; Andreu Vaquer; Enrique Barón; Steven M Russell; Marcio Borges; Roberto de la Rica
Journal:  Mikrochim Acta       Date:  2022-01-26       Impact factor: 5.833

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.