Literature DB >> 30797108

Novel chitosan-Nafion composite for fabrication of highly sensitive impedimetric and colorimetric As(III) aptasensor.

Sorour Salehi Baghbaderani1, Abdollah Noorbakhsh2.   

Abstract

In the present work, for the first time we takes the advantages of chitosan-Nafion (Chit-Naf) composite as a highly conductive surface platform and a novel CNT-based signal amplification strategy to develop a lable-free impedimetricaptamer-based sensor for highly sensitive detection of As(III). The electrochemical impedance spectroscopy (EIS) investigations surprisingly revealed that the glassy carbon electrode (GC) electrode modified with Chit-Naf composite had higher electron transfer kinetics compared the bare GC, GC/Naf and GC/Chit electrodes, which promises a great potential as an efficient platform in construction of biosensing assays. In this work, we employed a signal amplification strategy based on carbon nanotube-bovine serum albumin (CNT-BSA) hybrid system, by which sensitivity and detection limit of the aptasensor for the detection of As(III) were obtained to be 100.82 Ω nM-1 and a of 74 pM, respectively. This protocol provided one of the lowest limits of detection for As(III) on aptamer-based electrodes recently described in the literature. Moreover, the change of the optical absorptive properties of CNTs upon biorecognition interactions provides a way to detect the biorecognition process and thus allowed us to design an optical As(III) aptasensor using the UV-Vis spectroscopic method. The discrimination capability of the fabricated aptasensor for recognizing As(III) in the presence of other metal ions and a complex matrix of waste water samples was successfully investigated. This protocol provided a new method for sensitive detection of As(III) with considerable advantages in terms of reproducibility, selectivity, being mediator free and regenerability of the sensing interface.
Copyright © 2019 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Arsenic detection; CNT-based amplification strategy; Chitosan-Nafion; Electrochemicalaptasensor; Impedimetric

Mesh:

Substances:

Year:  2019        PMID: 30797108     DOI: 10.1016/j.bios.2019.01.059

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  6 in total

Review 1.  From Small Molecules Toward Whole Cells Detection: Application of Electrochemical Aptasensors in Modern Medical Diagnostics.

Authors:  Robert Ziółkowski; Marta Jarczewska; Łukasz Górski; Elżbieta Malinowska
Journal:  Sensors (Basel)       Date:  2021-01-21       Impact factor: 3.576

2.  Defect-enhanced electrochemical property of h-BN for Pb2+ detection.

Authors:  Yanling Shen; Huiying Ouyang; Weifeng Li; Yumei Long
Journal:  Mikrochim Acta       Date:  2021-01-13       Impact factor: 5.833

3.  Silica and graphene mediate arsenic detection in mature rice grain by a newly patterned current-volt aptasensor.

Authors:  M N A Uda; Subash C B Gopinath; Uda Hashim; N H Halim; N A Parmin; M N Afnan Uda; Tijjani Adam; Periasamy Anbu
Journal:  Sci Rep       Date:  2021-07-19       Impact factor: 4.379

Review 4.  Electrochemical Impedance Spectroscopy in the Characterisation and Application of Modified Electrodes for Electrochemical Sensors and Biosensors.

Authors:  Christopher M A Brett
Journal:  Molecules       Date:  2022-02-23       Impact factor: 4.411

Review 5.  Advances in Electrochemical Detection Electrodes for As(III).

Authors:  Haibing Hu; Baozhu Xie; Yangtian Lu; Jianxiong Zhu
Journal:  Nanomaterials (Basel)       Date:  2022-02-25       Impact factor: 5.076

Review 6.  What Electrochemical Biosensors Can Do for Forensic Science? Unique Features and Applications.

Authors:  Paloma Yáñez-Sedeño; Lourdes Agüí; Susana Campuzano; José Manuel Pingarrón
Journal:  Biosensors (Basel)       Date:  2019-10-29
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.