Literature DB >> 30795947

Interrater reliability of pediatric point-of-care lung ultrasound findings.

Cynthia A Gravel1, Michael C Monuteaux2, Jason A Levy3, Andrew F Miller4, Rebecca L Vieira5, Richard G Bachur6.   

Abstract

OBJECTIVE: We sought to assess interrater reliability (IRR) of lung point-of-care ultrasound (POCUS) findings among pediatric patients with suspected pneumonia.
METHODS: A convenience sample of patients between the ages of 6 months and 18 years with a clinical suspicion of pneumonia had a lung ultrasound performed by a POCUS-credentialed emergency medicine physician with subsequent expert review. Each lung zone was assessed as either normal or abnormal, and specific ultrasound findings were recorded. IRR was assessed by intraclass correlation coefficient (ICC) and kappa statistics.
RESULTS: Seventy-one patients, with a total of 852 lung zones imaged, were included. The sonographer assessment of normal versus abnormal, across each of the zones, demonstrated moderate agreement with ICC 0.46 (95% CI: 0.41, 0.52) and kappa 0.56. Right-sided zones demonstrated moderate agreement [0.43 (CI 0.35, 0.51)] while left-sided zones, specifically left-sided anterior zones, showed only fair agreement [0.36 (0.28, 0.44)]. IRR varied between specific findings: ICC for B-lines 0.52 (95% CI: 0.46, 0.57), pleural effusion 0.40 (0.34, 0.45), consolidation 0.39 (0.33, 0.44), subpleural consolidation 0.31 (0.25, 0.37), and pleural line irregularity 0.16 (0.10, 0.23). A composite indicator of typical pneumonia findings (consolidation, B-lines, and pleural effusion) demonstrated moderate [ICC 0.52 (0.46, 0.57)] reliability.
CONCLUSIONS: We found moderate interrater reliability of lung POCUS findings for the assessment of pediatric patients with suspected pneumonia. B-lines had the highest reliability. Further assessment of lung POCUS is necessary to guide proper training and optimal scanning techniques to ensure adequate reliability of ultrasound findings in the assessment of pediatric pneumonia.
Copyright © 2019 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Lung ultrasound; Pediatrics; Pneumonia; Point-of-care ultrasound

Mesh:

Year:  2019        PMID: 30795947     DOI: 10.1016/j.ajem.2019.01.047

Source DB:  PubMed          Journal:  Am J Emerg Med        ISSN: 0735-6757            Impact factor:   2.469


  9 in total

1.  The Inter-Rater Reliability of Pediatric Point-of-Care Lung Ultrasound Interpretation in Children With Acute Respiratory Failure.

Authors:  Ryan L DeSanti; Eileen A Cowan; Pierre D Kory; Michael R Lasarev; Jessica Schmidt; Awni M Al-Subu
Journal:  J Ultrasound Med       Date:  2021-08-11       Impact factor: 2.754

2.  Could It Be Pneumonia? Lung Ultrasound in Children With Low Clinical Suspicion for Pneumonia.

Authors:  Eric Scheier; Nadine Levick; Julia Peled; Uri Balla
Journal:  Pediatr Qual Saf       Date:  2020-07-07

Review 3.  Lung ultrasound in pediatric radiology - cons.

Authors:  Paolo Tomà
Journal:  Pediatr Radiol       Date:  2020-02-17

4.  Training and standardization of general practitioners in the use of lung ultrasound for the diagnosis of pediatric pneumonia.

Authors:  Farhan Pervaiz; Shakir Hossen; Miguel A Chavez; Catherine H Miele; Lawrence H Moulton; Eric D McCollum; Arun D Roy; Nabidul H Chowdhury; Salahuddin Ahmed; Nazma Begum; Abdul Quaiyum; Mathuram Santosham; Abdullah H Baqui; William Checkley
Journal:  Pediatr Pulmonol       Date:  2019-08-20

5.  Consensus on the Application of Lung Ultrasound in Pneumonia and Bronchiolitis in Children.

Authors:  Joanna Jaworska; Anna Komorowska-Piotrowska; Andrzej Pomiećko; Jakub Wiśniewski; Mariusz Woźniak; Błażej Littwin; Magdalena Kryger; Piotr Kwaśniewicz; Józef Szczyrski; Katarzyna Kulińska-Szukalska; Natalia Buda; Zbigniew Doniec; Wojciech Kosiak
Journal:  Diagnostics (Basel)       Date:  2020-11-11

6.  Interobserver Agreement of Lung Ultrasound Findings of COVID-19.

Authors:  Andre Kumar; Yingjie Weng; Sally Graglia; Sukyung Chung; Youyou Duanmu; Farhan Lalani; Kavita Gandhi; Viveta Lobo; Trevor Jensen; Jeffrey Nahn; John Kugler
Journal:  J Ultrasound Med       Date:  2021-01-11       Impact factor: 2.754

7.  CPIS Lung Ultrasound and the Erratic March toward Diagnostic Certainty in VAP.

Authors:  Ram E Rajagopalan
Journal:  Indian J Crit Care Med       Date:  2021-03

8.  Reliability and clinical correlations of semi-quantitative lung ultrasound on BLUE points in COVID-19 mechanically ventilated patients: The 'BLUE-LUSS'-A feasibility clinical study.

Authors:  Gábor Orosz; Pál Gyombolai; József T Tóth; Marcell Szabó
Journal:  PLoS One       Date:  2022-10-14       Impact factor: 3.752

Review 9.  Point-of-care ultrasound by the pediatrician in the diagnosis and follow-up of community-acquired pneumonia.

Authors:  Manuel Sobrino Toro; José Luis Vázquez Martínez; Ricardo Viana Falcão; Arnaldo Prata-Barbosa; Antonio José Ledo Alves da Cunha
Journal:  J Pediatr (Rio J)       Date:  2020-08-09       Impact factor: 2.990

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.