Literature DB >> 30794511

A Statistical Shape-Constrained Reconstruction Framework for Electrical Impedance Tomography.

Shangjie Ren, Kai Sun, Dong Liu, Feng Dong.   

Abstract

A statistical shape-constrained reconstruction (SSCR) framework is presented to incorporate the statistical prior information of human lung shapes for lung electrical impedance tomography. The prior information is extracted from 8000 chest-computed tomography scans across 800 patients. The reconstruction framework is implemented with two approaches-a one-step SSCR and an iterative SSCR in lung imaging. The one-step SSCR provides fast and high accurate reconstructions of healthy lungs, whereas the iterative SSCR allows to simultaneously estimate the pre-injured lung and the injury lung part. The approaches are evaluated with the simulated examples of thorax imaging and also with the experimental data from a laboratory setting, with difference imaging considered in both the approaches. It is demonstrated that the accuracy of lung shape reconstruction is significantly improved. In addition, the proposed approaches are proved to be robust against measurement noise, modeling error caused by inaccurately known domain boundary, and the selection of the regularization parameters.

Entities:  

Mesh:

Year:  2019        PMID: 30794511     DOI: 10.1109/TMI.2019.2900031

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  4 in total

1.  Calderón's Method with a Spatial Prior for 2-D EIT Imaging of Ventilation and Perfusion.

Authors:  Kwancheol Shin; Jennifer L Mueller
Journal:  Sensors (Basel)       Date:  2021-08-21       Impact factor: 3.847

2.  Artificial Intelligence Segmented Dynamic Video Images for Continuity Analysis in the Detection of Severe Cardiovascular Disease.

Authors:  Xi Zhu; Wei Xia; Zhuqing Bao; Yaohui Zhong; Yu Fang; Fei Yang; Xiaohua Gu; Jing Ye; Wennuo Huang
Journal:  Front Neurosci       Date:  2021-02-10       Impact factor: 4.677

3.  Improved resolution of D-bar images of ventilation using a Schur complement property and an anatomical atlas.

Authors:  Talles Batista Rattis Santos; Rafael Mikio Nakanishi; Erick Dario León Bueno de Camargo; Marcelo Brito Passos Amato; Jari P Kaipio; Raul Gonzalez Lima; Jennifer L Mueller
Journal:  Med Phys       Date:  2022-05-05       Impact factor: 4.506

4.  Focusing Sensor Design for Open Electrical Impedance Tomography Based on Shape Conformal Transformation.

Authors:  Yu Wang; Shangjie Ren; Feng Dong
Journal:  Sensors (Basel)       Date:  2019-05-02       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.