Literature DB >> 30790569

A randomized controlled trial of Dilapan-S vs Foley balloon for preinduction cervical ripening (DILAFOL trial).

Antonio F Saad1, Josephine Villarreal2, Joe Eid2, Nicholas Spencer2, Viviana Ellis2, Gary D Hankins2, George R Saade2.   

Abstract

OBJECTIVE: The objective of the study was to test the hypothesis that Dilapan-S is not inferior to the Foley balloon for preinduction cervical ripening at term. STUDY
DESIGN: Pregnant women ≥37 weeks scheduled for induction with unfavorable cervix (≤3 cm dilated and ≤60% effaced) were randomly assigned to 12 hours of either Foley balloon inflated with 60 mL saline or Dilapan-S for cervical ripening. If the cervix remained unfavorable, then 1 more round of the assigned dilator was used. Management following ripening was left up to the clinical providers. The primary outcome was vaginal delivery. A satisfaction survey was also obtained after the preinduction period. Sample size was based on a noninferiority margin of 10%, 90% power, and an estimated frequency of vaginal delivery of 71% in Foley balloon and 76% in Dilapan-S.
RESULTS: From November 2016 through February 2018, 419 women were randomized (209 to Foley balloon; 210 to Dilapan-S). In the intent-to-treat analysis, vaginal delivery was more common in Dilapan-S vs Foley balloon (81.3% vs 76.1%), with an absolute difference with respect to the Foley balloon of 5.2% (95% confidence interval, -2.7% to 13.0%) indicating noninferiority for the prespecified margin. The difference was not large enough to show superiority. Noninferiority was confirmed in the per-protocol population (n = 204 in the Foley balloon, n = 188 in Dilapan-S), supporting the robustness of the results. Secondary outcomes were not different between groups, except for a longer time the device remained in place in Dilapan-S compared with the Foley balloon. Maternal and neonatal adverse events were not significantly different between groups. A priori interaction analyses showed no difference in the effect on vaginal delivery by cervical dilation at randomization, parity, or body mass index >30 kg/m2. Patients with Dilapan-S were more satisfied than patients with the Foley balloon as far as sleep (P = .01), relaxing time (P = .001), and performance of desired daily activities (P = .001).
CONCLUSION: Dilapan-S is not inferior to the Foley balloon for preinduction cervical ripening at term. Advantages of Dilapan-S over Foley include Food and Drug Administration approval, safe profile, no protrusion from the introitus, no need to keep under tension, and better patient satisfaction.
Copyright © 2019 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Dilapan-S; cervical ripening; induction; labor; mechanical

Mesh:

Substances:

Year:  2019        PMID: 30790569     DOI: 10.1016/j.ajog.2019.01.008

Source DB:  PubMed          Journal:  Am J Obstet Gynecol        ISSN: 0002-9378            Impact factor:   8.661


  3 in total

1.  Outpatient Compared With Inpatient Preinduction Cervical Ripening Using a Synthetic Osmotic Dilator: A Randomized Clinical Trial.

Authors:  Antonio F Saad; Rachana Gavara; Rosemary Noel Senguttuvan; Arena D Goncharov; Marissa Berry; Joe Eid; Brett Goldman; Ana Nutter; Christopher P Moutos; Amanda M Wang; George R Saade
Journal:  Obstet Gynecol       Date:  2022-09-07       Impact factor: 7.623

2.  Out-of-Hospital Cervical Ripening With a Synthetic Hygroscopic Cervical Dilator May Reduce Hospital Costs and Cesarean Sections in the United States-A Cost-Consequence Analysis.

Authors:  Sita J Saunders; Rhodri Saunders; Tess Wong; Antonio F Saad
Journal:  Front Public Health       Date:  2021-06-18

Review 3.  Mechanical methods for induction of labour.

Authors:  Marieke Dt de Vaan; Mieke Lg Ten Eikelder; Marta Jozwiak; Kirsten R Palmer; Miranda Davies-Tuck; Kitty Wm Bloemenkamp; Ben Willem J Mol; Michel Boulvain
Journal:  Cochrane Database Syst Rev       Date:  2019-10-18
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.