Literature DB >> 30786314

Acoustic Radiation Force Impulse Elastography and Ultrasonographic Findings of Achilles Tendon in Patients With and Without Diabetic Peripheral Neuropathy: A Cross-Sectional Study.

Özlem Turhan İyidir1, Feride Kural Rahatlı2, Yusuf Bozkuş1, Lala Ramazanova1, Hale Turnaoğlu2, Aslı Nar1, Neslihan Başçıl Tütüncü1.   

Abstract

AIMS: We aimed to evaluate the elastographic features of Achilles tendon with Acoustic Radiation Force Impulse in patients with and without diabetic neuropathy.
METHODS: According to the presence of peripheral neuropathy, 45 patients with type 2 diabetes were divided into 2 subgroups. Those with peripheral neuropathy were defined as group I (22 patients) and those without peripheral neuropathy were defined as group II (23 patients). A total of thirty age-, gender-, and body mass index-matched healthy individuals were selected as controls. All participants underwent both ultrasonographic and Acoustic Radiation Force Impulse elastographic examination in order to evaluate Achilles Tendon thickness and stiffness.
RESULTS: Achilles tendon thicknesses were similar between groups (p=0.991). Achilles tendon thicknesses of both patient groups were significantly higher than the control group (group I vs control p=0.01; group II vs control p=0.006). Stiffness values of Achilles tendons were similar between the control group and group II (p=0.993). Shear Wave Velocity was significantly lower in group I than group IIand control group (p<0.001).
CONCLUSION: Diabetic patients with neuropathy have thicker and softer Achilles tendon while the elasticity of Achilles tendon in diabetic patients without neuropathy is similar to the healthy controls. Softening of the Achilles tendon may be an early sign of diabetic foot and reveal the patients with a risk of diabetic foot. Thieme. All rights reserved.

Entities:  

Year:  2019        PMID: 30786314     DOI: 10.1055/a-0840-3292

Source DB:  PubMed          Journal:  Exp Clin Endocrinol Diabetes        ISSN: 0947-7349            Impact factor:   2.949


  2 in total

1.  Human Achilles tendon mechanical behavior is more strongly related to collagen disorganization than advanced glycation end-products content.

Authors:  Jennifer A Zellers; Jeremy D Eekhoff; Remy E Walk; Mary K Hastings; Simon Y Tang; Spencer P Lake
Journal:  Sci Rep       Date:  2021-12-17       Impact factor: 4.379

2.  Evaluation of Achilles Tendon in Patients with Diabetic Foot Ulcer by High-Frequency Ultrasound Combined with Real-Time Shear-Wave Elastography.

Authors:  Fan Zhang; Juan Wang; Yulin Ma; Yi Wang; Wengang Wang; Yueheng Wang
Journal:  J Healthc Eng       Date:  2022-01-28       Impact factor: 2.682

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.