Literature DB >> 3078422

Ultrasound detection of micro-emboli in the middle cerebral artery during cardiopulmonary bypass surgery.

P B Deverall1, T S Padayachee, S Parsons, R Theobold, S A Battistessa.   

Abstract

The occurrence of neurological sequelae following cardiopulmonary bypass (CBP) surgery has stimulated interest in refining the techniques of extracorporeal circulation. Air micro-emboli originating from the oxygenator have been postulated as one source of cerebral damage. Since controversy still exists regarding the merits of bubble versus membrane oxygenators, this has prompted investigators to devise methods to determine the amount of micro-emboli produced during CPB. In this study, 27 patients undergoing CPB surgery for coronary artery disease (21) or valve replacement (6) were examined. The surgical and anaesthetic techniques were standardised in all patients except for the type of oxygenator used. A bubble oxygenator was used in 17 patients (Bentley Bio-10, William Harvey or Dideco) and a membrane oxygenator with a 25 microns filter in the remaining 10 patients (Bentley BOS CM50). Transcranial pulsed Doppler ultrasound was used to obtain blood velocity signals from the middle cerebral artery throughout CPB. A flow disturbance index (FDI) was defined which provided a representative index of the number of micro-emboli passing the ultrasound transducer. The FDI indicated the presence of gaseous micro-emboli during insertion of the aortic cannula in 22 of the 27 patients. In the 17 patients with a bubble oxygenator, the FDI ranged from 4-39. In the 10 patients with a membrane oxygenator, the FDI was always 0. Variation of gas flow rates in 3 patients with bubble oxygenators showed a change in the FDI from 4 +/- 4 at a flow rate of 2 l/min to 17 +/- 9 at 5 l/min.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1988        PMID: 3078422     DOI: 10.1016/1010-7940(88)90080-2

Source DB:  PubMed          Journal:  Eur J Cardiothorac Surg        ISSN: 1010-7940            Impact factor:   4.191


  5 in total

1.  Effects of myocardial contractility on microemboli production by mechanical heart valves in a bovine model.

Authors:  G Deklunder; J L Lecroart; J L Conger; D Lapeyre; I Gregoric; H Rose; D Tamez; O H Frazier
Journal:  Tex Heart Inst J       Date:  2000

Review 2.  Monitoring during paediatric cardiac anaesthesia.

Authors:  J P Purday
Journal:  Can J Anaesth       Date:  1994-09       Impact factor: 5.063

3.  Microemboli in our bypass circuits: a contemporary audit.

Authors:  Timothy W Willcox; Simon J Mitchell
Journal:  J Extra Corpor Technol       Date:  2009-12

4.  Diversity and metabolism of Woeseiales bacteria, global members of marine sediment communities.

Authors:  Katy Hoffmann; Christina Bienhold; Pier Luigi Buttigieg; Katrin Knittel; Rafael Laso-Pérez; Josephine Z Rapp; Antje Boetius; Pierre Offre
Journal:  ISME J       Date:  2020-01-27       Impact factor: 10.302

5.  Single cell analyses reveal contrasting life strategies of the two main nitrifiers in the ocean.

Authors:  Katharina Kitzinger; Hannah K Marchant; Laura A Bristow; Craig W Herbold; Cory C Padilla; Abiel T Kidane; Sten Littmann; Holger Daims; Petra Pjevac; Frank J Stewart; Michael Wagner; Marcel M M Kuypers
Journal:  Nat Commun       Date:  2020-02-07       Impact factor: 14.919

  5 in total